ATOMIZER CARD
CONTROLS
(See Figure 13)
Atomizer Speed Display
This two digit display indicates rotator speed in
rpm x 1000 (krpm) during normal speed control
operation. During fault conditions a two digit
fault code is displayed to indicate what fault has
occurred.
Figure 12: Front Panel Operating Controls
Speed Select Thumbwheel Switch
This switch is used in local mode to manually enter
the speed control setpoint in thousands of rpms
(krpm). Press the + or - switch buttons to incre-
ment or decrement the desired digit. After setting
the desired values, press the Speed Enter button
to confirm the new setpoint. If the setpoint is set
higher than the maximum allowable rotator speed,
"In" (invalid request) will flash in the speed display
until the setpoint is reduced below the maximum.