Octavia 1997
1.6 l/75 kW Engine, Fuel Injection and Ignition System
01-2
Self-diagnosis II
Fault codes 16486 ... 16990
Note
The fault table is arranged according to the 5-digit fault code on the left.
♦
The SAE code which is displayed on the right next to the fault code (e.g.. P0107) can be ignored (at present only
♦
valid for USA).
Explanations regarding fault types (e.g. „open circuit or short-circuit to earth") µ Operating instructions for the ve-
♦
hicle system tester.
If parts are output as faulty: First check all cables and connectors to these components as well as the earth con-
♦
nections according to the Current Flow Diagram. Only if no fault is detected here should the part be replaced. This
applies in particular if faults are shown as „sporadic" (SP).
If „literature" appears in the display of the vehicle system tester -V.A.G 1552- look for the text required in the fault
♦
table under the fault code.
Readout on -V.A.G 1552-
16486
Air mass meter -G70
16487
Air mass meter -G70
16496
Intake air temperature sender -
G42
16497
Intake air temperature sender -
G42
16500
Coolant temperature sender -
G62
16501
Coolant temperature sender -
G62
16502
Coolant temperature sender -
G62
16514
Bank 1, probe 1
16515
Bank 1, probe 1
16516
Bank 1, probe 1
16517
Bank 1, probe 1
16518
Bank 1, probe 1
16520
Bank 1, probe 2
Edition 10.04
S00.5135.52.20
Rectifying fault
Signal too low
–
Signal too high
–
–
–
Signal too low
–
–
Signal too high
–
Implausible signal
–
Signal too low
–
–
Signal too high
Electrical fault in the
circuit
Voltage too low
–
Voltage too high
Signal too slow
No activity
–
Electrical fault in the
circuit
Self-diagnosis II
Read measured value block, display group 002, display
field 4 µ Chap. 01-5.
Test wiring and plug connections according to current
flow diagram.
Testing intake system for leaks (unmetered air)
µ Chap. 24-2.
Replace air filter if necessary µ Chap. 24-1.
Read measured value block, display group 004, display
field 4 µ Chap. 01-5.
Test resistances µ Chapter 24-1.
Test wiring and plug connections according to current
flow diagram.
Read measured value block, display group 004, display
field 3 µ Chap. 01-5.
Test resistances µ Chapter 24-1.
Test wiring and plug connections according to current
flow diagram.
Test lambda probe -G39- and lambda control upstream
of catalytic converter µ Chapter 24-4.
Test lambda probe -G130- and lambda control down-
stream of catalytic converter µ Chapter 24-4
01
01-2
1
page