Skoda Octavia 1997 Workshop Manual page 14

1.6 i/75 kw engine, fuel injection and ignition system
Hide thumbs Also See for Octavia 1997:
Table of Contents

Advertisement

01
Readout on -V.A.G 1552-
16521
Bank 1, probe 2
16522
Bank 1, probe 2
16524
Bank 1, probe 2
16554
Bank 1, fuel metering system
16555
Bank 1, fuel metering system
16556
Bank 1, fuel metering system
16684
Combustion misfiring detected
16685
Cyl. 1 Combustion misfiring de-
tected
16686
Cyl. 2 Combustion misfiring de-
tected
16687
Cyl. 3 Combustion misfiring de-
tected
16688
Cyl. 4 Combustion misfiring de-
tected
16705
Engine speed sender -G28
16706
Engine speed sender -G28
16711
Knock sensor 1 -G61
16712
Knock sensor 1 -G61
01-2
2
page
Octavia 1997
Rectifying fault
Voltage too low
Voltage too high
No activity
Malfunction
System too lean
System too rich
Implausible signal
No signal
Signal too low
Signal too high
Self-diagnosis II
1.6 l/75 kW Engine, Fuel Injection and Ignition System
Test lambda probe -G130- and lambda control down-
stream of catalytic converter µ Chapter 24-4.
Test fuel pressure regulator and holding pressure
µ Chap. 24-2
Test injection valves µ Chapter 24-2
Test fuel pump µ 1.6/75 Engine, Mechanical Compo-
nents; Rep. Gr. 20
Inspect exhaust system for leaks µ 1.6/75 kW Engine,
Mechanical Components; Rep. Gr. 26
Inspect secondary air system for leaks µ 1.6/75 kW
Engine, Mechanical Components; Rep. Gr. 26
Inspect vacuum lines for leaks
Testing intake system for leaks (unmetered air)
µ Chap. 24-2.
Test lambda probe -G39- and lambda control upstream
of catalytic converter µ Chapter 24-4.
Test fuel pressure regulator and holding pressure
µ Chap. 24-2
Check the resistance values of the injectors (12...17 Ω
at approx. 20 °C).
Test ignition cables and spark plugs µ Chap. 28-1.
Test power output stage -N122- µ Chapter 28-1.
Read measured value block, display groups 014, 015
and 016 µ Chap. 01-5.
Test resistance of sender (730...1000 Ω).
Test wiring and plug connections according to current
flow diagram.
Replace engine speed sender -G28-.
Read measured value block, display groups 020, 026
and 028 µ Chap. 01-5.
Edition 10.04
S00.5135.52.20

Hide quick links:

Advertisement

Table of Contents
loading