Troubleshooting; Circuit Diagram - Vinotemp VT-BC-1 Owner's Manual

Vinotemp beverage cooler owner's manual
Table of Contents

Advertisement

Drip pan
• When the compressor stops working, water drops will drain through the
outlet in the inner back wall into the drain pan (above the compressor).
• If the drain pan needs to be cleaned, pull the drain pan forward gently
and reinstall it after cleaning.
If your cooler does not work properly, please note the following suggestions
before you attempt to repair.
Cooler does not work:
• Check the electrical outlet for power, and that the plug is properly
inserted.
• Check the condenser for proper cleaning.
• The circuit breaker is tripped or the fuse is blown.
Cooler makes too much noise:
• Check that the cooler is level.
Compressor turns on and off frequently:
• The room temperature is higher than normal.
• The door is not closed completely.
• The door gasket is not sealed well.
• There is insufficient clearance around the cooler.
• The temperature is not set properly.
• The cycling frequency will reduce when all of the cans reach the set
temperature.
The following is not a malfunction:
• It is normal to hear gurgling sounds caused by the flow of refrigerant
when each cooling cycle ends.
115V 60Hz
Control Enclosure
1 7 6 3 1 S o u t h S u s a n a R o a d , R a n c h o D o m i n g u e z , C a l i f o r n i a 9 0 2 2 1

TROUBLESHOOTING

CIRCUIT DIAGRAM

Sensor
Computerized Controller
Impedance
Impedance
coil
coil
Starter
i n f o @ v i n o t e m p . c o m
Overload
Protector
Compressor
C
S
M
Starter
PTC Starter
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vt-bc-01

Table of Contents