VMOC205SS
Pin No.
Signal
5
AN7
6
AN6
7-9
AN5-AN3
10
AN2
11
AN1
12
AN0
13
P55
14
P54
15
P53
16
P52
17
P51
I/O
IN
Used for initial balancing of the bridge circuit (absolute humidity sensor). This input
is an analog input terminal from the AH sensor circuit, and connected to the A/D
converter built into the LSI.
IN
AH sensor input.
This input is an analog input terminal from the AH sensor circuit, and connected to
the A/D converter built into the LSI.
IN
Heating constant compensation terminal.
IN
Input signal which communicates the door open/close information to LSI.
Door closed; "H" level signal(0V).
Door opened; "L" level signal(-5V).
IN
Input signal which communicates the damper open/close information to LSI.
Damper opened; "H" level signal(0V:GND).
Damper closed; "L" level signal(-5V).
IN
Temperature measurement input: OVEN THERMISTOR.
By inputting DC voltage corresponding to the temperature detected by the thermistor,
this input is converted into temperature by the A/D converter built into the LSI.
OUT
Digit selection signal.
The relationship between digit signal and digit are as follows;
Digit signal
P03 .......................... 1st.
P02 ......................... 2nd.
P01 .......................... 3rd.
P00 .......................... 4th.
P37 .......................... 5th.
P36 ......................... 6th.
P35 ......................... 7th.
P55 ......................... 8th.
Normally, one pulse is output in every ß
period, and input to the grid of the Fluores-
cent Display.
OUT
Oven lamp and turntable motor driving signal. (Square Waveform : 60Hz)
To turn on and off the shut-off relay(RY1).
The square waveform voltage is delivered to
the relay(RY1) driving circuit.
OUT
Convection motor driving signal.
To turn on and off shut-off relay(RY5). "L"
level during CONVECTION; "H" level other-
wise.
OUT
Cooling fan motor driving signal.
To turn on and off shut-off relay(RY6). "L"
level during both microwave and convection
cooking; "H" level otherwise.
OUT
Magnetron high-voltage circuit driving
signal.
To turn on and off the cook relay(RY2). In
P-HI operation, the signals holds "L" level
during microwave cooking and "H" level
while not cooking. In other cooking modes
(P-90, P-80, P-70, P-60, P-50, P-40, P-
30, P-20, P-10, P-0) the signal turns to "H"
level and "L" level in repetition according
to the power level.
Description
Digit
ß(60Hz)
P03
P02
P01
P00
P37
P36
P35
P55
VARI MODE
P-HI (100% power)
P-90 (approx. 90% power)
P-80 (approx. 80% power)
P-70 (approx. 70% power)
P-60 (approx. 60% power)
P-50 (approx. 50% power)
P-40 (approx. 40% power)
P-30 (approx. 30% power)
P-20 (approx. 20% power)
P-10 (approx. 10% power)
P-0 (0% power)
24
GND
VP
16.7 msec.
H
L
During cooking
H.
GND
During
OFF
cooking
(Convection)
ON
L
H.
OFF
During
cooking
ON
L
ON TIME
OFF TIME
32 sec.
30 sec.
26 sec.
24 sec.
22 sec.
18 sec.
16 sec.
12 sec.
8 sec.
6 sec.
0 sec.
H
L
GND
0 sec.
2 sec.
6 sec.
8 sec.
10 sec.
14 sec.
16 sec.
20 sec.
24 sec.
26 sec.
32 sec.

Hide quick links: