Samsung AVR-M100FHAX Installation Manual
Samsung AVR-M100FHAX Installation Manual

Samsung AVR-M100FHAX Installation Manual

Base heater control kit

Advertisement

Quick Links

Base heater Control KIT
Installation manual
Base heater Control box AVR-M100FHAX / AVR-M100JHAX
Thank you for purchasing this Samsung Product
Before operating this unit, please read this Installation manual carefully and retain it for future
reference.

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AVR-M100FHAX

  • Page 1 Base heater Control KIT Installation manual Base heater Control box AVR-M100FHAX / AVR-M100JHAX Thank you for purchasing this Samsung Product Before operating this unit, please read this Installation manual carefully and retain it for future reference.
  • Page 2: Table Of Contents

    Contents Safety Information Installation Control box parts diagram Accessories Installing the control box How to connect the power terminals Wiring diagram Configuring the options of the outdoor unit for installation of Base heater and control box Cautions for base heater and control box Appendix Check items by error code 2 English...
  • Page 3: Safety Information

    Safety Information Be sure to use copper wire as the power cable and use only WARNING the regulated parts for wiring. Be sure to check whether wiring has been properly made. Cancer and Reproductive Harm - www.P65Warnings. ca.gov. Otherwise, it may cause heating to result in fire. WARNING CAUTION Before installation, service or maintenance of this product...
  • Page 4: Installation

    Product Body (1) Installation Guide (1) Sub PCB assembly Fuse Transformer Relay Bracket Holder (1) M4 x L12 Screw (5) Terminal block <AVR-M100FHAX> Sub PCB assembly Fuse Relay Terminal block Unit: mm (inch) 60 (2.36) 120 (4.72) 39 (1.54) 145 (5.71)
  • Page 5: Installing The Control Box

    Control Box Installation Installing the control box Fasten the bracket to the to the control box's body using the supplied screws. The bracket should be installed Fasten the control box to the outdoor unit with supplied screws (3 EA) for assembly. (in case of a large model, fold down the cover top and then perform assembly.) (in case of a large model, remove the screw from the...
  • Page 6 Control Box Installation Secure the motor wire that connects to the control box on holder. Be careful not to touch the control box's body. Transmission wires Transmission wires Power supply wires Connect the Transmission and power wires between Power supply wires control box.
  • Page 7: How To Connect The Power Terminals

    How to connect the power terminals CAUTION When stripping the wire, be sure to use the dedicated tool Secure the base heater wires as shown in the figure. not to damage the inner sheath. When wiring the base heater control box, use wire Have the outer sheath of the indoor unit's power and connectors with compression connection.
  • Page 8: Wiring Diagram

    Control Box Installation Wiring diagram For 460 V CN83 (RED) B14 PBA CN81 (RED) CN48 (BLU) HUB PBA FUSE FUSE (250V,F2A) L1 L2 230V TRANS 460V T1 T2 1(L) 2(N) L BASEHEATER1 BASEHEATER2 For 220 V CN83 (RED) B14 PBA CN81 (RED) CN48...
  • Page 9: Configuring The Options Of The Outdoor Unit For Installation Of Base Heater And Control Box

    Configuring the options of the outdoor In the option setup menu, when you shortly press the K1 switch, the values for Segment 1 and Segment 2 change. unit for installation of Base heater and You can select the desired option. control box (e.g.
  • Page 10: Cautions For Base Heater And Control Box

    If the option is not set, an error occurs so normal operation may not be possible. To obtain the updated outdoor unit firmware, please reach out to your local Samsung HVAC service or distribution center. Check whether the control box relay operates properly.
  • Page 11: Appendix

    Check items by error code Symptom During the Heat mode or the heater test run, the temperature on the heater does not increase. 1) Connection error 2) Outside temperature sensor error Cause 3) Heater power connection error 4) Relay operation error The connector is properly Check operation after connecting the connected between the heater...
  • Page 12 Check items by error code Symptom 1) Test run Cause 2) Outside temperature sensor error 3) Relay operation error Commissioning is in progress? It operates normally. Check operation after removing foreign The outside temperature materials, or connecting or replacing the sensor operates normally? sensor.
  • Page 13 Memo English...
  • Page 14 Memo English...
  • Page 15 English...
  • Page 16 DB68-08019A-00...

This manual is also suitable for:

Avr-m100jhax

Table of Contents