Installation Manual
Label
Color
FAIL
Red
-
ACT
Green
Yellow
-
BITS/SETS
Green
STATUS (1
& 2)
Red
-
BITS/SETS
Green
ACT SRC
(1 & 2)
Red
-
PWR
Green
-
SWAP
Blue
READY
-
Version 5.8
Table 2-17: SA/M3K Blade LEDs Description
Status
On
Blade failure (fatal error).
Off
Normal operation.
On
Active blade (applicable only to Mediant 3000 HA configuration)
initialization sequence completed successfully.
On
Standby blade (applicable only to Mediant 3000 HA configuration)
initialization sequence terminated successfully.
Blinking
Blade initialization sequence terminated successfully.
Off
Standalone blade.
On
Framer locked on BITS clock.
Note: Each LED (1 or 2) depicts the BITS source connected
either to the upper or lower PEM module on the device's rear
panel. Therefore, only one of the LEDs is applicable (they change
only if the BITS source is changed).
On
Timing source failure.
Off
This BITS clock reference is not used.
On
Active clock source.
Note: Each LED (1 or 2) depicts the BITS source connected
either to the upper or lower PEM module on the device's rear
panel. Therefore, only one of the LEDs is applicable (they change
only if the BITS source is changed).
On
Timing source failure.
Off
This is not an active source.
On
Blade receiving power.
Off
No power received by blade.
On
Blade can been fully inserted or extracted (after being partially
inserted or extracted).
Off
Blade has been successfully inserted (not ready to be extracted).
Description
35
2. Physical Description
July 2009