1. PV INPUT terminals connection
Open the cover through the lock catch on right bottom of Power Pack.
PV connecting terminals are waterproof. Put the cable through terminal
block, and crimp the end into cold-pressed terminals, then finish the
connection in accordance with the PV+ and the PV-.
Operation Instruction
1. Loosen the waterproof
terminal cap, rotate the nut in
counterclockwise to remove
the terminal caps
.
2.Put cable through the
waterproof terminal block, and
then crimp the end into
cold-pressed terminals.
3. Connect the cold-pressed
terminals correctly according
to the "PV+" and "PV-" which
are marked on the terminal
board
In accordance with the above steps, fixing the positive and negative
terminals of PV arrays onto the Power Pack's input terminal one by one.
Operation Demonstration
PV+
PV-