VERSION 5 UPDATE GUIDE
HARDWIRED
CONTROL UNITS

Advertisement

Table of Contents
loading

Summary of Contents for Cooper Security Scantronic 9853

  • Page 1 9x5x VERSION 5 UPDATE GUIDE HARDWIRED CONTROL UNITS...
  • Page 2: Table Of Contents

    © Cooper Security Ltd. 2007 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security Limited accept any liability for loss or damage caused or alleged to be caused directly or indirectly by this book. The contents of this book are subject to change without notice.
  • Page 3: Introduction

    This Update Guide describes the new features and changes introduced to the 9853, 9752 and 9751 with version 5.0x software. The changes described in this guide are apply to the following manuals: Updated manuals are available on the Cooper Security web site at www.coopersecurity.co.uk 2. Changes To Hardware The control unit can now operate on 60Hz 230VAC mains supplies.
  • Page 4: Command 81 To 84 - Option 38

    Command 81 to 84 - Option 38 This option is now active for the following faults: AC Fail, Anti-Mask, Aux DC, Battery Load Test Fail, Battery Missing, Comms Fail, Jamming, Keypad Ident Fail, Line Fail (internal communicator only), Low Battery, RF Low Battery, Supervision Fail, Telecommand Low Battery, uCom Fail, Zone AC Fail, Zone Battery Fault, Zone Fault, Zone Low Battery and Zone Pwr O/P.
  • Page 5 KEYPAD MEDICAL KEYPAD FIRE KEYPAD PA LID TAMPER LID TAMPER RESTORE 137‡ MAN TRIGGER TEST REPORT PANIC (see note 2) PANIC RESTORE 120‡ PERIODIC TEST REPORT SENSOR SELF TEST FAILURE SENSOR TAMPER SENSOR TAMPER RESTORE 137‡ SMOKE DETECTOR SMOKE DETECTOR RESTORE 111‡...
  • Page 6: Command 141: Alert Tone On/Off

    LOW BATT RESTORE (see note 6) 311‡ PARTITION RESET RESET INTERMEDIATE Event SIA Code CID Code DISARM KEYSWITCH DISARM KEYSWITCH ARM ZONE FAULT ZONE FAULT RESTORE FULL Event SIA Code CID Code COMMS FAIL DOWNLOAD SUCCESS EXCESS KEYS EXPANDER MISSING EXPANDER MISSING RESTORE 137‡...
  • Page 7: Command 151 To 158: Plug-By Communicator Outputs

    Option Disabled. The display shows alert messages for faults, but does not sound alert tones. Enabled (default). The display shows alert messages, and the system gives alert tones. Command 151 to 158: Plug-by Communicator Outputs 1. Note that All Fault is active for the following faults: AC Fail, Anti-Mask, Aux DC, Battery Load Test Fail, Battery Missing, Comms Fail, Jamming, Keypad Ident Fail, Line Fail (internal communicator only), Low Battery, RF Low Battery, Supervision Fail, Telecommand Low Battery, uCom Fail,...
  • Page 8: Downloader Calling Control Unit

    Downloader Calling Control Unit The end user can now control access to the control unit for incoming calls from Downloader. To do this the user: Keys in an access code (or presents a tag). Presses 0. The display shows: Call CS Presses B and then y.