Hold & Decay Active Out - Schippmann CS-8 Series Owner's Manual

Dtg
Hide thumbs Also See for CS-8 Series:
Table of Contents

Advertisement

Voltage
+5 V
+5 V
8.5 Hold & Decay active out
Jack 13 provides a Hold input function. A +5 V signal causes a "freezing" of the
envelope
output
(Attack/Decay/Release) are kept unaffected. The envelope continues its
progress only again by deactivating the Hold input (0 V). With changing the
Env-Gate state at jack 8 during "Hold" the generator will initialized with
another phase, but executed only after deactivating the "Hold". Presupposition
is to untie the internal connection between Env-Reset (jack 12) and Env-Gate
(jack 8), otherwise any new transition from 0 V to +5 V will cause a reset.
The Decay active output (jack 16) always provides a +5 V signal during the
Decay-Phase. Fig. 8 illustrates the described processes.
Fig. 7 Envelope reset
voltage,
immediately.
-19-
CS-8 Series DTG Rev1.3, July 2020
Env Out
time
Env Reset
time
Env Gate
time
The
current
time
phases

Advertisement