Schippmann CS-8 Series Owner's Manual page 12

Dtg
Hide thumbs Also See for CS-8 Series:
Table of Contents

Advertisement

1.
Gate jack (input) – generates, caused by a 0 V -> +5 V transition, a +5 V
Gate signal of definite length at
definite delay time at
2.
Gate O jack (output) – provides a +5 V Gate signal of definite length or by
a definite delay time in relation to the Gate input
3.
G-Time controller – set the Gate length in Gate mode or the delay time in
delay mode, resp. between 50 µs to 10 seconds
4.
1 V/Dec. jack (input) – set by an external voltage the Gate length/delay
time by a sensitivity of 1 V/decade, positive/negative voltage ->
shorter/longer by a factor of 10 per volt from the current state
5.
Gt/Del jack (input) – selects between Gate mode and Delay mode,
+5 V -> Gate, 0V -> Delay; is tied by a switching contact to +5 V and is
unused in Gate mode
6.
LED indicator – lights up in Delay mode firstly "red", when a Gate signal is
incoming at
becomes active
7.
Gt-Res jack (input) – reset, as long as a +5 V input is applied, the active
jack (2
Gate at
tied by a switching contact to
means a "low" (0 V) at
8.
Env-Gate jack (input) – a +5 V starts the envelope attack or maintaining
the decay phase; 0 V set the envelope always into the release phase
9.
1 V/Dec. jack (input) – set by an external voltage the Attack time by a
sensitivity of 1 V/decade, positive/negative voltage -> faster/slower by a
factor of 10 per volt from the current state
10. Attack controller – set the Attack time between 100 µs to 20 seconds
11. LED indicator – shows by its brightness the current envelope output
value during the attack phase, "green" at positive output values, "red" for
negative ones
12. Env-Res jack (input) – reset by a 0 V -> +5 V transition the envelope
output to 0 V and the generator back to the attack phase; is tied by a
switching contact to
envelope start
13. Hold jack (input) – "freezes", as long as a +5 V signal is applied and held,
the envelope output to the current voltage state
14. 1 V/Dec. jack (input) – set by an external voltage the Decay time by a
sensitivity of 1 V/decade, positive/negative voltage -> faster/slower by a
factor of 10 per volt from the current state
15. Decay controller – set the Decay time between 100 µs to 20 seconds
jack (2)
jack (1)
and changes to "green" when the Gate O at
) and inhibits a new start
jack (8)
jack (8)
CS-8 Series DTG Rev1.3, July 2020
jack (2) (Gate O)
(1)
(not active in Delay mode); is
jack (8)
(Env-Gate) and works inverse,
causes a reset!
(10)
(Env-Gate) and causes a reset with the
(15)
-10-
; or outputs it by a
(1)
(3)
jack (2)