Schippmann CS-8 Series Owner's Manual page 14

Dtg
Hide thumbs Also See for CS-8 Series:
Table of Contents

Advertisement

32. Gt-Res jack (input) – reset, as long as a +5 V input is applied, the active
jack (27
Gate at
tied by a switching contact to
means a "low" (0 V) at
33. Env-Gate jack (input) – a +5 V starts the envelope attack or maintaining
the decay phase; 0 V set the envelope always into the release phase
34. 1 V/Dec. jack (input) – set by an external voltage the Attack time by a
sensitivity of 1 V/decade, positive/negative voltage -> faster/slower by a
factor of 10 per volt from the current state
35. Attack controller – set the Attack time between 100 µs to 20 seconds
36. LED indicator – shows by its brightness the current envelope output
value during the attack phase, "green" at positive output values, "red" for
negative ones
37. Env-Res jack (input) – reset by a 0 V -> +5 V transition the envelope
output to 0 V and the generator back to the attack phase; is tied by a
switching contact to
envelope start
38. Hold jack (input) – "freezes", as long as a +5 V signal is applied and held,
the envelope output to the current voltage state
39. 1 V/Dec. jack (input) – set by an external voltage the Decay time by a
sensitivity of 1 V/decade, positive/negative voltage -> faster/slower by a
factor of 10 per volt from the current state
40. Decay controller – set the Decay time between 100 µs to 20 seconds
41. Dec-Act. jack (output) - provides a +5 V signal during the decay phase
42. LED indicator – shows by its brightness the current envelope output
value during the decay phase, "green" at positive output values, "red" for
negative ones
43. Sustain controller – set the final value of the decay phase between
-100% (-5 V) und +100% (+5 V)
44. CV-Sus jack (input) - set by an external voltage of -5 V - +5 V (at middle
position of
und +200% (+10 V); decay becomes at >100% a second attack!
45. LED indicator – shows by its brightness the current envelope output
value during the release phase, "green" at positive output values, "red" for
negative ones
46. Release controller – set the release time between 100 µs to 20 seconds
47. 1 V/Dec. jack (input) – set by an external voltage the release time by a
sensitivity of 1 V/decade, positive/negative voltage -> faster/slower by a
factor of 10 per volt from the current state
) and inhibits a new start
jack (33)
jack (33)
(43)
) the final value of the decay phase between -200% (-10 V)
CS-8 Series DTG Rev1.3, July 2020
(26)
(not active in Delay mode); is
jack (33)
(Env-Gate) and works inverse,
causes a reset!
(35)
(Env-Gate) and causes a reset with the
(40)
(46)
-12-