Optional Lifebreath Wireless Timer - Part #99-DET02
The
timer
will
override
(regardless of
the settings)
Ventilation. Upon completion of the timer cycle, the HRV
will return to your selected operational mode and speed
setting.
Initiates HIGH speed ventilation for 20, 40 or 60 minutes. The
20/40/60
minute
Status
operation.
The Wireless Timers are to be surface mounted onto a
wall. Multiple Wireless Timers may be installed in a ventilation
system.
To increase the range of a Wireless Timer, a RX02
Repeater should be used.
Pairing:
1. Turn on the main wall control by pressing the ON/OFF
button
and remove the battery from Timer.
2. DET02 with DXPL02 Controls:
right buttons simultaneously on the main wall control
(
and RESET buttons). The screen will go blank and
the wireless symbol
bottom right of the display. This indicates that the main
control is now in pairing mode. (Figure D)
3. DET02 with BC02, BC03 and BC04 Controls:
Press the left and right buttons simultaneously on the
main wall control (
and either
depending on the main control). The bottom row of 3
LED's will begin flashing. This indicates that the main
control is now in pairing mode.(Figure E)
4. Keep the Timer within 16" of the main wall control when
pairing.
5. Install the battery in the DET02 Timer. All four lights on
the Timer will immediately flash 5 times, then only the
red battery light will remain on for approximately 12
seconds after which the "40" light flashes the rev code.
20, 40, 60 lights will flash until paired or will stop if not
paired within 12 seconds. If pairing was not successful
you now must return to step 1 to restart the pairing
process.
6. Press the
button on the main wall control to exit
pairing mode when Timers have been successfully
paired.
To pair additional DET02 Timers with the same wall control, or if pairing
was not successful, repeat steps 1-6.
When paired, the DET02 Timers can be moved and installed elsewhere.
Estimated range of the Timer is 40' with no obstructions. A RX02 Repeater may
be installed to increase the range of the Timers.
Test if pairing was successful by pressing the Select Button and listen for the
HRV to initiate HIGH fan speed Ventilation.
Un-pairing:
1. Remove the battery from the back of the DET02 Timer
2. Press and hold the Select Button on the front of the Timer
3. While holding the Select Button, reinsert the battery in the Timer. Continue holding the Select
Button until the LED under "40" begins flashing. The DET02 Timer will now be unpaired with the
main wall control.
the
operational
and
initiate
HIGH
Lights
indicate
HIGH
Press the left and
will appear flashing on the
or
buttons,
mode
speed
The Wireless Timers and Repeaters must be
matched to the main wall control of the HRV.
This process
speed
Timers and Repeaters can be paired to a single
wall control.
Figure A
Back Plate
Face Plate
Alternate Wall Mount
Break off tab
1/8 in hole for
screw and anchor
Break off tab
14
ATTENTION
is
called
"Pairing".
Figure B
1/8 in hole for
screw and
anchor
1/8 in hole
for screw and
anchor
Figure C
Figure D
BC02, BC03 or
BC04 Control
NOTE:
Your BC
1/8 in
control may look
hole for
different than the
screw and
one shown.
anchor
Press Simultaneously to
Initiate Pairing Mode
Figure E
DET02 Timer
Removable
Backplate
20/40/60 Minute
Status Lights
Select Button
initiates high speed
ventilation for 20, 40
or 60 min.
Battery Indicator