4. TECHNICAL CHARACTERISTICS

Power supply
Tension
Frequency
Energy consumption
Fuses
Input
Outlet
Keeping the memory which can be
erased when there is a power cut
Outlets Number
6,12,18+1 (according to model)
Type
By relay contact, with potential of 24
VAC (Internal transformer) or 12VDC
Limits
40 VAC / 30 VDC, 1 Amp
Atmosphere
Temperature
Humidity
Height
Pollution
Memory backup
DECLARATION OF CONFORMITY
It follows the
89/336/CEE Guidelines for the Electromagnetic Compatibility and the
73/23/CEE Guidelines of Low Tension for the Fulfilment of the Product Security. The
fulfilment of the following specifications was demonstrated as indicated in the Official Diary
of the European Communities:
Emissions EN 50081-1:94
Immunity EN 50082-1:94
Harmonics
Fluctuations
Low tension guidelines
Symbols which may appear
in the product
This symbol indicates that the electrical and electronic equipment should not be disposed of as
general household waste at its end-of-life. Instead, the product should be handed over to the
applicable collection point for the recycling of electrical and electronic equipment for proper
treatment, recovery and recycling in accordance with your national legislation.
Units for alternating current
230 VAC +5% -10% CAT II
50 - 60 Hz
Inferior to 58 VA (at rest 2,7 VA)
0.630 A, T type, 250V (slow)
2 A, F type, 250V (fast)
Battery, more than 72 hours
0º C to 45º C
< 85 %
2000 m
Grade II
Clock, consults
Programme, parameters
EN 55022:1995 Class B Radiated and conducted emissions.
EN 61000-4-2 (95)
EN 61000-4-3 (96)
EN 61000-4-4 (95)
EN 61000-4-5
EN 61000-4-11
EN 61000-3-2 (95)
EN 61000-3-3 (95)
EN 61010-1
Protection earth
terminal
12 VDC +10% -5%
--------
Inferior to 7 W (at rest 0,6 W)
0.8 A, T type, 250V (slow)
3.15 A, F type, 250V (fast)
Condenser, 24 hours
Inputs
Number 5
Type
Weight
(approximate) Unit to build-in
Battery or condenser
Non erasable
Immunity to electrostatic discharges.
Immunity to the electromagnetic field of radioelectric
frequency.
Immunity to fast transitional in common way.
Immunity to overloads in the power supply.
Immunity to lacks and power cuts.
Current harmonics.
Tension fluctuations.
Security requirements of measurement electric units,
control and use in laboratory.
Danger, risk of
electroshock
Units for direct current
Optolinked, to connect to
contacts free of potential
Unit in mounting box
Double
insulation
7
2,2 Kg
2,7 Kg