16
6. Trigger Mode Setting
Nomal
Restart
shutter
reset
mode
mode
5
5
6
6
6.1.
Normal Shutter Mode
Each scan modes are available. In addition, input and output of VD / HD signals.
6.2.
Restart Reset Mode
By inputting restart/reset signals (VD/HD) from an external device, you can obtain information for one screen at an
arbitrary timing.
VD enter at intervals of greater than 1V+5H.
Long-time exposure
By extending the CCD accumulation time using the restart/reset function, you can obtain high-sensitivity images.
It is useful when sensitivity is insufficient under normal usage conditions, or to observe the tracks of a moving object.
To do this, input a VD signal that has a longer period between VD pulses (T in the figure) from an external device.
Caution
During long-time exposure, noticeable white flecks may appear.
Non
Reset
reset
mode
mode
5
5
6
6
16/36