Advertisement

Alarms

Alarm Set-
Item
point
Negative
<-5%LEL
Alarm
Default
Low
10%LEL
Alarm
Default
High
20%LEL
Alarm
Default
N/A
TWA
Default
N/A
STEL
Over
>100%LEL
Alarm
Gas
Setting Res-
Type
olution
NDIR-
1% LEL
CH4
BW Icon
Resseting
Keep alarm until reading
increase above or equal to -
5%LEL
Keep alarm until reading
decease to below 10%LEL
Keep alarm until reading
decease to below 20%LEL
Keep alarm until reading
increase over 100%LEL
Low Alarm Set-
ting Range
5~60%
5~60%
Silence when transmitting data
to Device Configurator or IR
Link
Silence when transmitting data
to Device Configurator or IR
Link
Silence when transmitting data
to Device Configurator or IR
Link
Silence when transmitting data
to Device Configurator or IR
Link
High Alarm Set-
ting Range
N/A
28
Silencing
TWA Set-
STEL Setting
ting range
Range
N/A
User Manual