2. Service Information
2-1. How to reset the HOUR METER
DIAG MENU HOURS METER
*H00 OPERATION
H01 DRUM RUN
H02 TAPE RUN
H03 THREADING
H11 DRUM RUNr
H12 TAPE RUNr
H13 THREADINGr
H30 POWER ON
END
1. Turns power OFF and set the DIP SW 501-1 to ON position on the SYSCON (F2)
P.C.B.
2. Turns power ON and press DIAG button and then press SEARCH button. Confirm the
HOUR METER information is displayed on the monitor as above figure.
3. Set the cursor to mark "r" position by rotating the jog JOG DIAL then press the
RESET button.
4. The message is displayed as below. (The following message is a example when "DRUM
RUN r ".)
DRUM RUN r OK?
YES<PLAY> NO<STOP>
When PLAY button is pressed, a reset function is executed.
When STOP button is pressed, a reset function is canceled.
5. Set the DIP SW 501-1 to OFF position on the SYSCON (F2) P.C.B.
Note
Accumulated Time can not be reset.
*****H
*****H
*****H
*****T
0H
0H
0T
*****T
----- Accumulated Drum Run
----- Accumulated Tape Run
----- Accumulated Threading