connecting tabs, strike the head of the screwdriver
lightly with a hammer to break the tabs. Swing the plate
outward and bend it back and forth to break the top
tabs. Both knockout plates must be removed in order
to attach the register assembly properly. If the inner shield
knockout is not embossed deep enough to be removed
easily, mark an outline using the existing opening as a
guide. Use tin snips to cut the area away. A pilot hole may
be needed to begin the first cut. Take care not to damage
the combustion chamber directly behind the inner shield
when making a pilot hole.
4.
Attach speed nuts to the outer shield (Figure B). After the
furnace is in position, insert the outlet register into the
opening as shown in Figures C, D and E. Install machine
screws through the register housing and into the speed
nut clips on the furnace outer shield. Do not over tighten
the screws.
5.
After the register has been either wired, (Figure F), or
plugged in, set the fan switch to the desired blower
operation.
CAUTION: Do not install this kit where the outlet grille
may be blocked or covered by a door, curtains or any
other obstructions.
FIGURE A – Recessed & Surface Installation
FIGURE B – Removing Knockout Plates
INNER SHIELD
10 - 24 SPEED
NUT
ACCESSORY SIDE
OPENING SIZE
8 1/4ʺ X 13 3/8ʺ
45ʺ
FLOOR PLATE
KNOCKOUT PLATE
ON OUTTER SHIELD
HOLD SCREWDRIVER
SIDEWAYS AGAINST
TABS AND STRIKE
LIGHTLY WITH
HAMMER
FIGURE C – Surfaced Mounted Installation
FURNACE
SHEILDS
FIGURE D – Recessed Mounted Installation
FURNACE
SHEILDS
JUNCTION
BOX
REGISTER
ASSEMBLY
HEAT SENSOR
SWITCH
BLOWER AND
MOTOR
NAIL FLANGE OF
PLASTER GROUND
TO 2 X 4
HEAT SENSOR
SWITCH
BLOWER AND
MOTOR
23