Siemens SITRANS T Series Compact Operating Instructions page 47

Hide thumbs Also See for SITRANS T Series:
Table of Contents

Advertisement

Table 7-6
Type 2N
Temperature class
Temperature
Temperature
of medium (°C)
rise caused by
medium ΔT2G
(K)
100 °C
7
80 °C
5
Gas hazardous area: Ex d / XP
The maximum ambient temperatures T
transmitter can be obtained from the cells in the following tables. The temperature increase
given by the medium is already considered there.
Table 7-7
Gas Ex d
Temperature class
Max. permitted power consump‐
tion of electronic (W)
Medium tem‐
Extension
perature (°C)
length "X"
(mm)
440 °C
40
80
150 ... 300
290 °C
40
80 ... 300
200 °C
40
80 ... 300
130 °C
40 ... 300
80 °C
40 ... 300
For the determination of ambient temperatures, maximum enclosure temperature of 85 °C was taken as a basis when
1)
electronic are incorporated.
SITRANS TS100/TS200/TS300/TS500/TSinsert/TSthermowell
Compact Operating Instructions, 08/2020, A5E03920348-AF
Header type
BA0: BB0; BC0; BD0; AA0, AB0,
AC0, KJ0, BS0, AG0
T
Header
max
T4
T
in °C
2
100
100
Head type
AH0, AV0, SI‐
TRANS TF
T
head
85 °C
max
T6
0 ... 3
1)
With or with‐
out electronic
T
in °C
a_max
43
55
61
54
61
58
63
61
67
BMO, BT0,
100 °C
80 °C
T6
T
in °C
T
2
73
80
for the respective connection head with or without
a
AG0, UG0
100 °C
T4
0
1 ... 3
Without elec‐
With electron‐
tronic
T
in °C
T
a_max
a_max
76
88
94
87
94
91
96
94
100
7.1 Rated conditions
BP0
AH0
100 °C
T6
T4
in °C
T
in °C
2
2
73
100
80
100
AU0, UU0
120 °C
T3
0
1)
Without elec‐
ic
tronic
in °C
T
in °C
a_max
53
96
65
108
71
114
64
107
71
114
68
111
73
116
71
114
77
120
Technical data
T6
T
in °C
2
73
80
T4
1 ... 3
1)
With electron‐
ic
T
in °C
a_max
48
60
66
59
66
63
68
66
72
47

Advertisement

Table of Contents
loading

Table of Contents