Page 2
FlatClient HYG – Rev. 1.0 This page has been intentionally left blank www.kontron.com // 2...
Page 3
In cases of doubt, please contact Kontron. This user guide is protected by copyright. All rights are reserved by Kontron. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), without the express written permission of Kontron.
Page 4
ENVIRONMENTAL DAMAGE (COLLECTIVELY, "HIGH RISK APPLICATIONS"). You understand and agree that your use of Kontron devices as a component in High Risk Applications is entirely at your risk. To minimize the risks associated with your products and applications, you should provide adequate design and operating safeguards.
Page 5
If you have any difficulties using this user guide, discover an error, or just want to provide some feedback, contact Kontron support. Detail any errors you find. We will correct the errors or problems as soon as possible and post the revised user guide on our website.
FlatClient HYG – Rev. 1.0 Symbols The following symbols may be used in this user guide DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Therefore, in the interest of your own safety and of the correct operation of your new Kontron product, you are requested to conform with the following guidelines.
FlatClient HYG – Rev. 1.0 Lithium Battery Precautions If your product is equipped with a lithium battery, take the following precautions when replacing the battery. Danger of explosion if the battery is replaced incorrectly. Replace only with same or equivalent battery type recommended by the manufacturer.
General Instructions on Usage In order to maintain Kontron’s product warranty, this product must not be altered or modified in any way. Changes or modifications to the product, that are not explicitly approved by Kontron and described in this user guide or received from Kontron Support as a special handling instruction, will void your warranty.
FlatClient HYG – Rev. 1.0 Quality and Environmental Management Kontron aims to deliver reliable high-end products designed and built for quality, and aims to complying with environmental laws, regulations, and other environmentally oriented requirements. For more information regarding Kontron’s quality and environmental responsibilities, visit http://www.kontron.com/about-kontron/corporate- responsibility/quality-management.
FlatClient HYG – Rev. 1.0 Table of Contents Symbols ..........................................6 For Your Safety ........................................7 High Voltage Safety Instructions .................................. 7 Special Handling and Unpacking Instruction ............................7 Lithium Battery Precautions ..................................8 General Instructions on Usage..................................9 Quality and Environmental Management ..............................10 Disposal and Recycling ....................................
Figure 4: Rear View Arm Mount Version ..............................18 Figure 5: Rear View VESA Mount Version ..............................19 Figure 6: FlatClient HYG Arm Version Block Diagram Board ......................20 Figure 7: FlatClient HYG VESA Version Block Diagram Board ......................21 Figure 8: LAN-Connector Cable...................................
1/ Introduction With its FlatClient HYG Monitor series, Kontron offers high mechanical flexibility with respect to the design. It can be used as VESA 100 solution as well as a support-arm solution. The support-arm variant offers an IP69K protection, the VESA variant an IP67 protection.
FlatClient HYG – Rev. 1.0 2/ Scope of Delivery This chapter describes the components that are delivered. Please check that your delivery is complete and contains the items below (according to the ordered unit configuration). If you discover damaged or missing items, please contact your dealer.
FlatClient HYG – Rev. 1.0 3/ Accessories This chapter describes the components that can be optionally ordered. Table 3: FlatClient HYG Accessories Part Number Part Description 1066-7603 Dust cover USB - IP67 protected 1066-7601 External USB-A 3.0 IP67 protected cable, 2 m one...
FlatClient HYG – Rev. 1.0 3.1.1. Type Label and Product Identification Product and Package Label, size 85 x 35mm, polyester matt silver. Certifications such as UL or FCC can be requested optionally. Figure 2: Type Label Short Description Part-Number Barcode Series#...
FlatClient HYG – Rev. 1.0 Figure 5: Rear View VESA Mount Version 2x stub for optional connectors 1x USB VESA 100 (red circles, use M4 screws with a maximal penetration 8 mm and typical 1.3 Nm torque) 1x LAN Power Connector Vent www.kontron.com...
FlatClient HYG – Rev. 1.0 5/ Technical Data and Environmental Specification Table 4: Technical Data FlatClient HYG Display Size ECO Line PRO Line Resolution (pixel) 1920x1080 1920x1080 Format 16:9 16:9 300 cd/m² 300 cd/m² Brightness LED Lifetime (> 50%, 25°C) >...
Page 23
FlatClient HYG – Rev. 1.0 Table 5: Dimensions FlatClient HYG Display Variant VESA Arm mounted Dimensions (WxHxD in mm) 542 x 366 x 74 542 x 366 x 126 Mounting VESA 100 with M12 connector support arm on 48 mm tube Weight ~ 8.5 kg...
FlatClient HYG – Rev. 1.0 6/ Order Information E N 0 0 - y y y y y y - x x Internal Code (Standard FlatClient) YY: CPU Y8 = Intel® Pentium® Quad Core™ YD = Intel® Core™ i5-6300U XD = Intel® Core™ i5-7300U WD = Intel®...
FlatClient HYG – Rev. 1.0 8/ Connectors 8.1. External Connectors 8.1.1. External Connectors for Arm Mount Variant The support arm variant comes with included cables. Number, length and Type depends on the system configuration. Power is always required, LAN and USB in most cases.
FlatClient HYG – Rev. 1.0 Table 9: Pinout USB 3.0 Signal Name Signal Name +USB_VCC USB_RX- USB_D- USB_RX+ USB_D+ USB_TX- USB_TX+ 8.1.3. External Connectors for VESA Mount Variant 8.1.3.1. Power male M12 A-coded Connector IP67 Protected Figure 10: M12 A-coded Power Connector...
FlatClient HYG – Rev. 1.0 Table 11: USB 3.0 Connector IP67 Protected Signal Name +5 V USB-A output (900 mA max.) USB-A D- USB-A D+ Ground USB-A Rx- USB-A Rx+ GND_Drain USB-A Tx- USB-A Tx+ The shield is connected to the cage 8.1.3.3.
To activate your FlatClient Panel PC connect the power supply to power connector on the FlatClient back side. Alternative use the mating power connector for connecting your power cable. Don´t hesitate to ask for support: e-mail: support@kontron.com Phone: +49 (0)89 37 00 58 - 0 All essential drivers you´ll find on www.kontron.com www.kontron.com // 30...
FlatClient HYG – Rev. 1.0 10/ Technical Support For technical support, please contact Kontron http://www.kontron.com/support To request support via e-mail, report documentation errors, or general customer feedback, use Kontron’s Contact Support form by visiting: http://www.kontron.com/about-kontron/company-overview/contact-us/forms/contact-support. In case the request form does not work or you do not get a response within 48 hours, follow up with support@kontron.com...
RMA number. The Buyer accepts responsibility for all freight charges for the return of goods to Kontron's designated facility. Kontron will pay return freight charges back to the Buyer's location in the event that the equipment is repaired or replaced within the warranty period stipulated herewith.
FlatClient HYG – Rev. 1.0 Appendix A: List of Acronyms Application Programming Interface Base Management Controller Command-Line Interface Computer-on-Module Error Checking and Correction Field Replaceable Unit Graphics Processing Unit HD/HDD Hard Disk /Drive PICMG Hardware Platform Management specification family Internet of Things...
FlatClient HYG – Rev. 1.0 About Kontron Kontron is a global leader in embedded computing technology (ECT). As a part of technology group S&T, Kontron offers a combined portfolio of secure hardware, middleware and services for Internet of Things (IoT) and Industry 4.0 applications. With its...
Need help?
Do you have a question about the FlatClient HYG and is the answer not in the manual?
Questions and answers