Page 2
Fusion Client – User Guide (Rev. 1.3) This page has been intentionally left blank.
Page 3
In cases of doubt, please contact Kontron. This user guide is protected by copyright. All rights are reserved by Kontron. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), without the express written permission of Kontron.
Page 4
ENVIRONMENTAL DAMAGE (COLLECTIVELY, "HIGH RISK APPLICATIONS"). You understand and agree that your use of Kontron devices as a component in High Risk Applications is entirely at your risk. To minimize the risks associated with your products and applications, you should provide adequate design and operating safeguards.
If you have any difficulties using this user guide, discover an error, or just want to provide some feedback, contact Kontron support. Detail any errors you find. We will correct the errors or problems as soon as possible and post the revised user guide on our website.
Fusion Client – User Guide (Rev. 1.3) Symbols The following symbols may be used in this user guide DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
FusionClient – User Guide (Rev. 1.3) For Your Safety Your new Kontron product was developed and tested carefully to provide all features necessary to ensure its compliance with electrical safety requirements. It was also designed for a long fault-free life.
Dispose of used batteries according to the manufacturer’s instructions. General Instructions on Usage In order to maintain Kontron’s product warranty, this product must not be altered or modified in any way. Changes or modifications to the product, that are not explicitly approved by Kontron and described in this user guide or received from Kontron Support as a special handling instruction, will void your warranty.
Page 10
EEE Improve the environmental performance of all those involved during the lifecycle of EEE Environmental protection is a high priority with Kontron. Kontron follows the WEEE directive You are encouraged to return our products for proper disposal.
9.2.4. (X12) Serial Port (RS422/RS485) configured as RS485 (2-Wire Mode), half duplex ......78 Technical Support ............................... 79 10.1. Returning Defective Merchandise ............................ 79 About Kontron ....................................80 List of Tables Table 1: FusionClient - Scope of delivery ..........................21 Table 2: FusionClient –...
Page 14
Figure 37: Mechanical specification - Front view of the FC 215 ..................71 Figure 38: Mechanical specification - Rear view of the FC 215 ..................71 Figure 39: Mechanical specification - Side view of the FC 215 ..................72 www.kontron.com // 14...
• The power consumption of any add-on card does not exceed the specified limitations. • The current consumption of the system does not exceed the value stated on the product label. Only original accessories that have been approved by Kontron can be used. ...
Use antistatic mats, heel straps, or air ionizers for more protection. Always handle electrostatically sensitive components by their edge or by their casing. Avoid contact with pins, leads, or circuitry. Turn off power and input signals before inserting and removing connectors or connecting test equipment. www.kontron.com // 16...
Page 17
Keep work area free of non-conductive materials such as ordinary plastic assembly aids and Styrofoam. Use only field service tools which are conductive, such as cutters, screwdrivers, and vacuum cleaners. Always place drives and boards PCB-assembly-side down on the foam. www.kontron.com // 17...
UL recognized. Do not dispose of lithium batteries in general trash collection. Dispose of the battery according to the local regulations dealing with the disposal of these special materials, (e.g. to the collecting points for dispose of batteries). www.kontron.com // 18...
Kontron Europe GmbH. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.
Page 20
The method of compliance is self-declaration to Canadian ICES-003: (English): This Class B digital apparatus complies with the Canadian ICES-003. (French) : Cet appareil numérique de la Class B est conforme à la norme NMB-003 du Canada. www.kontron.com // 20...
3.1.2. Accessory Parts Table 4: FusionClient – Optional Accessories External AC/DC adapter (90-264 V AC/24 V DC), including power cable for EU and US. Mating connector (DC power terminal for DC power supply) is supplied with the system. www.kontron.com // 22...
FusionClient system. The FusionClient system expands the Kontron line of Human Machine Interface (HMI). The FusionClient is a system designed for demanding industrial applications. It integrates a workstation system with an integrated touch screen display.
Page 24
FusionClient – User Guide (Rev. 1.3) FusionClient provides a self-protection turn off function if the temperature sensors will measure an internal temperature level out of the limits (85°C). Refer to the section 6.4 “System Self Protection against Ambient Overheating”. www.kontron.com // 24...
Page 25
Installation by using of a VESA 75/100 compliant mounting system must be properly designed to support the heavy load of the FusionClient system. No user-serviceable parts inside. Do not open the FusionClient system. The following sections detail each of these components and their function in the FusionClient. www.kontron.com // 25...
To get the maximum buffer time, it is necessary to have the system for at least 1 day powered on. This ensures that the buffer capacitors are fully loaded. The buffer time depends on the ambient temperature and on how long the system is connected to the power supply. www.kontron.com // 26...
(GoldCap 100% of time at specified temperature, data provided by GoldCap manufacturer). 4.1.3. Optional Lithium Battery In addition to the GoldCap, an optional lithium battery can be installed. The lithium battery must be ordered separately and will be factory-installed. www.kontron.com // 27...
FusionClient – User Guide (Rev. 1.3) 4.2. Product Images of FusionClient (shown as 15.6", other units similar) Figure 4: Bottom view Figure 5: Right Figure 6: Front view Figure 7: Left view view Figure 8: Top view Figure 9: Rear view www.kontron.com // 28...
The integrated touch screen registers contacts of fingers and allows the user to operate the system without a keyboard or a pointing device. The implemented touch technology allows 10-touch operations www.kontron.com // 29...
Page 30
For information about the required touch screen driver refer to section 6.3 “Operating System and Hardware Component Drivers”. For technical specification of the built-in display and touch screen refer to chapter 8/ “Technical Data”. www.kontron.com // 30...
For technical specifications, refer to section 8.5. 4.3.5. Light Bar The light bar is equipped with multi-color LEDs and provides the following features: RGB color spectrum Permanent lighting and blinking modes configurable Blinking frequency and pulse duty factor configurable www.kontron.com // 31...
Air openings at the bottom side of the computer base 6x screws that secure the front panel (cover with cooling fins) to the cover with cooling fins of the computer base Touch display unit Figure 12: Power, control indicators, interfaces www.kontron.com // 33...
(Figure 12, pos. 11) has to be grounded to an appropriate “common earth” connection point (refer to 6.2.2 “DC Power Connection”. 4.4.3. Controls and Indicators Figure 14: FusionClient - Controls and Indicators Power Button Power LED Storage activity LED www.kontron.com // 34...
Performing a forced shut down can lead to loss of data or other undesirable effects! Please note the BIOS setup settings (BIOS Setup/Advanced/South Cluster Configuration/Miscellaneous Configuration/State after G3 –S0 State). “Power On” is the default setting. Please also note the description in section 6.4 “System Self Protection against Ambient Overheating”. www.kontron.com // 35...
9 and Figure 14, pos. 3) may be blinking as shown in Table 6. Table 6: Storage activity LED colors indicate the storage media activity System Activity of the installed Storage Media Color of the storage activity LED www.kontron.com // 36...
4.4.6. X5/X6 - USB 2.0 The FusionClient provides two USB 2.0/1.1 interfaces. These connectors (X5/X6, Figure 12, pos. 4) allow connection of USB 2.0 or USB 1.1 compatible devices to the system. For pin assignment, refer to subsection 9.1.4. www.kontron.com // 37...
SD card activity is indicated by the storage activity LED (Figure 12, pos. 9) of the FusionClient. This interface permits hot-plugging of the SD card. The system can also be booted from this interface. www.kontron.com // 38...
4.4.10. X10 – Optional Ethernet Connector This optional connectors (X10, Figure 12, pos. 12) is a Gigabit Ethernet 10/100/1000 Mb/s, IEEE 1588 capable interface. The connectors is a standard, 8-pin RJ45 type connector. For pin assignment, refer to subsection 9.1.6. www.kontron.com // 39...
4.4.11. X 11 – Optional serial Port COM2 (RS232) The RS232 interface (X 11, Figure 12, pos. 13), if ordered, is provided as a 9-pin D-SUB connector. It allows you to connect a serial device to the system. For pin assignment, refer to subsection 9.2.1. www.kontron.com // 40...
The FC 156 system will be secured into a wall/panel by use of: four mounting clamps at the top and bottom side two mounting clamps at the left and right side www.kontron.com // 41...
Note for mounting clamps: The FC 215 and FC 185 system will be secured into a wall/panel by use of: four mounting clamps at the top and bottom side three mounting clamps at the left and right side www.kontron.com // 42...
Air exhaust openings on the top side pf the touch display unit When powering on the FusionClient, make sure that the air intake and exhaust openings are not obstructed and the cooling fins not covered by objects. www.kontron.com // 43...
Page 44
The FC 121 system will be secured into a wall/panel by use of: two mounting clamps at the top and bottom side two mounting clamps at the left and right side www.kontron.com // 44...
The chassis may be hot during operation and should not be touched without taking care. The material on bottom surface of the enclosure interior where the FusionClient is to be mounted, shall keep at least flammability class UL 94-5VB. Don’t put www.kontron.com // 45...
Page 46
FusionClient – User Guide (Rev. 1.3) flammable materials under the device. www.kontron.com // 46...
Figure 24: Optional AC/DC adapter Power LED of the AC/DC adapter AC/DC adapter DC power connector (Connector to the AC power For connecting the FusionClient to AC power mains refer to subsection 6.2.3 “AC Power Connection”. www.kontron.com // 47...
The mounting clamps with screws (supplied), allow the easy and fast mounting of the FusionClient FC 121/FC 156/ FC 185/FC 215. The outline and mounting drawing can be found on our web site www.kontron.com. Table 7: FusionClient - Specification for mounting...
Page 50
FusionClient – User Guide (Rev. 1.3) Mounting position Ensure the vertical and horizontal alignment of the system/display unit. Refer to the note for mounting clamps in section 4.5 “Left and Right Side View”. www.kontron.com // 50...
Always use two hands when carrying the device. The glass front of the FusionClient is provided with edge protection and a protective foil. Only remove this protective material after the installation of the FusionClient. www.kontron.com // 51...
The maximum thickness of the wall/panel is 6 mm. Refer to Table 7 and Figure 25 for the wall/panel cutout dimensions or to the corresponding mechanical drawings for your FusionClient on our web site www.kontron.com. The system must be properly powered down and disconnected from the power source and peripherals.
[refer to Figure 27, Figure 13 or subsection 9.1.1 “(X1) Power Input Connector”]. Fasten the screws to secure the wires into the clamps of the plug terminal. Close the cover (Figure 27, pos. 2). www.kontron.com // 53...
The wires used for power connections must be clearly marked (+/-/grounding) to ensure that they will be proper connected to the DC connector of the FusionClient and to the main power source, corresponding the signals marked (refer to Figure 13). www.kontron.com // 54...
Page 55
Connect the other ends of the DC power wires to the connections of the DC main power supply. Pay attention to the polarity of the connections. Switch on the disconnecting device (circuit breaker) in order to apply voltage to the terminals of the power wires. www.kontron.com // 55...
“15-30V DC”. Make sure the connector is securely locked in place. Connect the AC power cord to the AC/DC adapter. Plug the AC connector of the adapter into an AC wall outlet of the AC power source. www.kontron.com // 56...
(optional hardware components) yourself. You can download the relevant drivers for the installed hardware from our web site at www.kontron.com by selecting the product. Pay attention to the manufacturer specifications of the operating system and the integrated hardware components.
Wet the glass plate with a microfiber cloth lightly moistened with warm water and mild glass cleaner. 7.2. Replacing the Lithium Battery The lithium battery is located on the installed carrier board and is not a serviceable part. Please contact Kontron support if the lithium battery needs to be replaced. www.kontron.com // 59...
Power LED LED Indicators (on the bottom side) Storage activity LED DC IN Power Plug 3 pin Phoenix connector On the bottom side (on the bottom side) Power DC: external 15-30 V power source (limited power source) www.kontron.com // 60...
Page 61
AC: via the optional external AC/DC adapter (limited power source) not included Lithium Battery (option) Type: CR2032; 3.0 V; 0.22Ah; VESA 75/100 On the rear IP20 rear Protection Class IP65 front (only mounted to a wall/panel) The table is continued on the next page. www.kontron.com // 61...
EN 60950-1 to connect the FusionClient to an AC power source. FusionClient FC 121 FC 156 FC 185 FC 215 Power 15-30 V DC Power consumption 3.0 A max. 3.0 A max. 3.5 A max. 3.5 A max. www.kontron.com // 62...
FusionClient – User Guide (Rev. 1.3) 8.2. Mechanical Specifications For detailed mechanical dimensions, please see the outline dimensions drawings on the web site www.kontron.com. FusionClient FC 121 FC 156 FC 185 FC 215 Height 266 mm (10.47") 298 mm (11.73") 337 mm (13.27")
FusionClient – User Guide (Rev. 1.3) Figure 28: Mechanical specification - Front view of the FC 121 Figure 29: Mechanical specification - Rear view of the FC 121 www.kontron.com // 64...
FusionClient – User Guide (Rev. 1.3) Figure 31: Mechanical specification - Front view of the FC 156 Figure 32: Mechanical specification - Rear view of the FC 156 www.kontron.com // 66...
FusionClient – User Guide (Rev. 1.3) Figure 34: Mechanical specification - Front view of the FC 185 Figure 35: Mechanical specification - Rear view of the FC 185 www.kontron.com // 68...
FusionClient – User Guide (Rev. 1.3) Figure 37: Mechanical specification - Front view of the FC 215 Figure 38: Mechanical specification - Rear view of the FC 215 www.kontron.com // 71...
Lane 2 (n) Lane 3 (p) GND (ML Lane 3) Lane 3 (n) AUX SEL# Pull-down to GND AUX CH (p) GND (AUX CH) AUX CH (n) Hot Plug 3.3V (DDC EEPROM GND (GND_DDC) power 500 mA fused www.kontron.com // 75...
RMA No. e-mail: service@kontron.com Ensure that you have received an RMA number from Kontron Customer Services before returning any device. Write this number clearly on the outside of the package. Describe the fault that has occurred.
FusionClient – User Guide (Rev. 1.3) About Kontron Kontron is a global leader in embedded computing technology (ECT). As a part of technology group S&T Kontron offers a combined portfolio of secure hardware, middleware and services for Internet of Thing (IoT) and Industry 4.0 applications.
Need help?
Do you have a question about the FusionClient FC 121 and is the answer not in the manual?