Table of Contents

Advertisement

Quick Links

FusionClient
Fusion Client – User Guide (Rev. 1.3)
Doc ID: 1060-3249

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FusionClient FC 121 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kontron FusionClient FC 121

  • Page 1 FusionClient Fusion Client – User Guide (Rev. 1.3) Doc ID: 1060-3249...
  • Page 2 Fusion Client – User Guide (Rev. 1.3) This page has been intentionally left blank.
  • Page 3 In cases of doubt, please contact Kontron. This user guide is protected by copyright. All rights are reserved by Kontron. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), without the express written permission of Kontron.
  • Page 4 ENVIRONMENTAL DAMAGE (COLLECTIVELY, "HIGH RISK APPLICATIONS"). You understand and agree that your use of Kontron devices as a component in High Risk Applications is entirely at your risk. To minimize the risks associated with your products and applications, you should provide adequate design and operating safeguards.
  • Page 5: Revision History

    If you have any difficulties using this user guide, discover an error, or just want to provide some feedback, contact Kontron support. Detail any errors you find. We will correct the errors or problems as soon as possible and post the revised user guide on our website.
  • Page 6: Symbols

    Fusion Client – User Guide (Rev. 1.3) Symbols The following symbols may be used in this user guide DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 7 Fusion Client – User Guide (Rev. 1.3)
  • Page 8: For Your Safety

    FusionClient – User Guide (Rev. 1.3) For Your Safety Your new Kontron product was developed and tested carefully to provide all features necessary to ensure its compliance with electrical safety requirements. It was also designed for a long fault-free life.
  • Page 9: Lithium Battery Precautions

    Dispose of used batteries according to the manufacturer’s instructions. General Instructions on Usage In order to maintain Kontron’s product warranty, this product must not be altered or modified in any way. Changes or modifications to the product, that are not explicitly approved by Kontron and described in this user guide or received from Kontron Support as a special handling instruction, will void your warranty.
  • Page 10 EEE Improve the environmental performance of all those involved during the lifecycle of EEE  Environmental protection is a high priority with Kontron. Kontron follows the WEEE directive You are encouraged to return our products for proper disposal.
  • Page 11: Table Of Contents

    4.3.2.1. Projected Capacitive Touch Screen ..........................31 4.3.3. RFID Card Reader (Option) ..............................31 4.3.4. Integrated WiFi Module (Option) ............................ 31 4.3.5. Light Bar ....................................31 4.4. Bottom Side (with Interfaces) ............................33 4.4.1. (X1) - DC Power Input Connector ............................. 34 www.kontron.com // 11...
  • Page 12 8.2. Mechanical Specifications ..............................63 8.3. Environmental Specifications .............................. 73 8.4. CE-Directives, Standards and Approvals ........................74 8.5. WiFi Specification (Option) ..............................74 8.6. RFID Specification (Option) ..............................74 9/ Standard Interfaces – Pin Assignments ........................75 www.kontron.com // 12...
  • Page 13: List Of Tables

    9.2.4. (X12) Serial Port (RS422/RS485) configured as RS485 (2-Wire Mode), half duplex ......78 Technical Support ............................... 79 10.1. Returning Defective Merchandise ............................ 79 About Kontron ....................................80 List of Tables Table 1: FusionClient - Scope of delivery ..........................21 Table 2: FusionClient –...
  • Page 14 Figure 37: Mechanical specification - Front view of the FC 215 ..................71 Figure 38: Mechanical specification - Rear view of the FC 215 ..................71 Figure 39: Mechanical specification - Side view of the FC 215 ..................72 www.kontron.com // 14...
  • Page 15: 1/ General Safety Instructions For It Equipment

    • The power consumption of any add-on card does not exceed the specified limitations. • The current consumption of the system does not exceed the value stated on the product label. Only original accessories that have been approved by Kontron can be used. ...
  • Page 16: Electrostatic Discharge (Esd)

    Use antistatic mats, heel straps, or air ionizers for more protection. Always handle electrostatically sensitive components by their edge or by their casing. Avoid contact with pins, leads, or circuitry. Turn off power and input signals before inserting and removing connectors or connecting test equipment. www.kontron.com // 16...
  • Page 17 Keep work area free of non-conductive materials such as ordinary plastic assembly aids and Styrofoam. Use only field service tools which are conductive, such as cutters, screwdrivers, and vacuum cleaners. Always place drives and boards PCB-assembly-side down on the foam. www.kontron.com // 17...
  • Page 18: Hot Surface Warning

    UL recognized. Do not dispose of lithium batteries in general trash collection. Dispose of the battery according to the local regulations dealing with the disposal of these special materials, (e.g. to the collecting points for dispose of batteries). www.kontron.com // 18...
  • Page 19: 2/ Electromagnetic Compatibility (Class B Device)

    Kontron Europe GmbH. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.
  • Page 20 The method of compliance is self-declaration to Canadian ICES-003: (English): This Class B digital apparatus complies with the Canadian ICES-003. (French) : Cet appareil numérique de la Class B est conforme à la norme NMB-003 du Canada. www.kontron.com // 20...
  • Page 21: 3/ Scope Of Delivery

    COM Express® module 1x 2.5” SATA SSD drive (internal) 1x mSATA SSD, full/half size eMMC Flash Drive 2-64GB (only with E3845 installed, depending on the ordered COM Express® module) mPCIe Card 1x mPCIe card (full/half size) www.kontron.com // 21...
  • Page 22: Optional System Configuration

    3.1.2. Accessory Parts Table 4: FusionClient – Optional Accessories External AC/DC adapter (90-264 V AC/24 V DC), including power cable for EU and US. Mating connector (DC power terminal for DC power supply) is supplied with the system. www.kontron.com // 22...
  • Page 23: 4/ Product Description

    FusionClient system. The FusionClient system expands the Kontron line of Human Machine Interface (HMI). The FusionClient is a system designed for demanding industrial applications. It integrates a workstation system with an integrated touch screen display.
  • Page 24 FusionClient – User Guide (Rev. 1.3) FusionClient provides a self-protection turn off function if the temperature sensors will measure an internal temperature level out of the limits (85°C). Refer to the section 6.4 “System Self Protection against Ambient Overheating”. www.kontron.com // 24...
  • Page 25 Installation by using of a VESA 75/100 compliant mounting system must be properly designed to support the heavy load of the FusionClient system. No user-serviceable parts inside. Do not open the FusionClient system. The following sections detail each of these components and their function in the FusionClient. www.kontron.com // 25...
  • Page 26: Rtc (Goldcap)

    To get the maximum buffer time, it is necessary to have the system for at least 1 day powered on. This ensures that the buffer capacitors are fully loaded. The buffer time depends on the ambient temperature and on how long the system is connected to the power supply. www.kontron.com // 26...
  • Page 27: Rtc Buffer Aging

    (GoldCap 100% of time at specified temperature, data provided by GoldCap manufacturer). 4.1.3. Optional Lithium Battery In addition to the GoldCap, an optional lithium battery can be installed. The lithium battery must be ordered separately and will be factory-installed. www.kontron.com // 27...
  • Page 28: Product Images Of Fusionclient (Shown As 15.6", Other Units Similar)

    FusionClient – User Guide (Rev. 1.3) 4.2. Product Images of FusionClient (shown as 15.6", other units similar) Figure 4: Bottom view Figure 5: Right Figure 6: Front view Figure 7: Left view view Figure 8: Top view Figure 9: Rear view www.kontron.com // 28...
  • Page 29: Front View

    The integrated touch screen registers contacts of fingers and allows the user to operate the system without a keyboard or a pointing device. The implemented touch technology allows 10-touch operations www.kontron.com // 29...
  • Page 30 For information about the required touch screen driver refer to section 6.3 “Operating System and Hardware Component Drivers”. For technical specification of the built-in display and touch screen refer to chapter 8/ “Technical Data”. www.kontron.com // 30...
  • Page 31: Projected Capacitive Touch Screen

    For technical specifications, refer to section 8.5. 4.3.5. Light Bar The light bar is equipped with multi-color LEDs and provides the following features: RGB color spectrum  Permanent lighting and blinking modes configurable  Blinking frequency and pulse duty factor configurable  www.kontron.com // 31...
  • Page 32 FusionClient – User Guide (Rev. 1.3) www.kontron.com // 32...
  • Page 33: Bottom Side (With Interfaces)

    Air openings at the bottom side of the computer base 6x screws that secure the front panel (cover with cooling fins) to the cover with cooling fins of the computer base Touch display unit Figure 12: Power, control indicators, interfaces www.kontron.com // 33...
  • Page 34: X1) - Dc Power Input Connector

    (Figure 12, pos. 11) has to be grounded to an appropriate “common earth” connection point (refer to 6.2.2 “DC Power Connection”. 4.4.3. Controls and Indicators Figure 14: FusionClient - Controls and Indicators Power Button Power LED Storage activity LED www.kontron.com // 34...
  • Page 35: Power Button And Power Led

    Performing a forced shut down can lead to loss of data or other undesirable effects! Please note the BIOS setup settings (BIOS Setup/Advanced/South Cluster Configuration/Miscellaneous Configuration/State after G3 –S0 State). “Power On” is the default setting. Please also note the description in section 6.4 “System Self Protection against Ambient Overheating”. www.kontron.com // 35...
  • Page 36: Power Led And Storage Activity Led

    9 and Figure 14, pos. 3) may be blinking as shown in Table 6. Table 6: Storage activity LED colors indicate the storage media activity System Activity of the installed Storage Media Color of the storage activity LED www.kontron.com // 36...
  • Page 37: X2/X3 - Ethernet Connectors

    4.4.6. X5/X6 - USB 2.0 The FusionClient provides two USB 2.0/1.1 interfaces. These connectors (X5/X6, Figure 12, pos. 4) allow connection of USB 2.0 or USB 1.1 compatible devices to the system. For pin assignment, refer to subsection 9.1.4. www.kontron.com // 37...
  • Page 38: X7 - Rs232 Serial Port (Com1)

     SD card activity is indicated by the storage activity LED (Figure 12, pos. 9) of the FusionClient.  This interface permits hot-plugging of the SD card. The system can also be booted from this interface.  www.kontron.com // 38...
  • Page 39: X9 - Displayport

    4.4.10. X10 – Optional Ethernet Connector This optional connectors (X10, Figure 12, pos. 12) is a Gigabit Ethernet 10/100/1000 Mb/s, IEEE 1588 capable interface. The connectors is a standard, 8-pin RJ45 type connector. For pin assignment, refer to subsection 9.1.6. www.kontron.com // 39...
  • Page 40: 11 - Optional Serial Port Com2 (Rs232)

    4.4.11. X 11 – Optional serial Port COM2 (RS232) The RS232 interface (X 11, Figure 12, pos. 13), if ordered, is provided as a 9-pin D-SUB connector. It allows you to connect a serial device to the system. For pin assignment, refer to subsection 9.2.1. www.kontron.com // 40...
  • Page 41: 12 - Optional Serial Port Com3 (Rs422/Rs485)

     The FC 156 system will be secured into a wall/panel by use of: four mounting clamps at the top and bottom side  two mounting clamps at the left and right side  www.kontron.com // 41...
  • Page 42: Air Openings On The Bottom Side Of The Touch Display Unit

    Note for mounting clamps: The FC 215 and FC 185 system will be secured into a wall/panel by use of: four mounting clamps at the top and bottom side  three mounting clamps at the left and right side  www.kontron.com // 42...
  • Page 43: Top Side

    Air exhaust openings on the top side pf the touch display unit When powering on the FusionClient, make sure that the air intake and exhaust openings are not obstructed and the cooling fins not covered by objects. www.kontron.com // 43...
  • Page 44  The FC 121 system will be secured into a wall/panel by use of: two mounting clamps at the top and bottom side  two mounting clamps at the left and right side  www.kontron.com // 44...
  • Page 45: Rear Side

    The chassis may be hot during operation and should not be touched without taking care. The material on bottom surface of the enclosure interior where the FusionClient is to be mounted, shall keep at least flammability class UL 94-5VB. Don’t put www.kontron.com // 45...
  • Page 46 FusionClient – User Guide (Rev. 1.3) flammable materials under the device. www.kontron.com // 46...
  • Page 47: Gasket On The Rear Side

    Figure 24: Optional AC/DC adapter Power LED of the AC/DC adapter AC/DC adapter DC power connector (Connector to the AC power For connecting the FusionClient to AC power mains refer to subsection 6.2.3 “AC Power Connection”. www.kontron.com // 47...
  • Page 48 FusionClient – User Guide (Rev. 1.3) www.kontron.com // 48...
  • Page 49: 5/ Installation Instructions

    The mounting clamps with screws (supplied), allow the easy and fast mounting of the FusionClient FC 121/FC 156/ FC 185/FC 215. The outline and mounting drawing can be found on our web site www.kontron.com. Table 7: FusionClient - Specification for mounting...
  • Page 50 FusionClient – User Guide (Rev. 1.3) Mounting position Ensure the vertical and horizontal alignment of the system/display unit. Refer to the note for mounting clamps in section 4.5 “Left and Right Side View”. www.kontron.com // 50...
  • Page 51: Figure 25: Wall/Panel Cutout Dimensions For Fusionclient Systems

    Always use two hands when carrying the device. The glass front of the FusionClient is provided with edge protection and a protective foil. Only remove this protective material after the installation of the FusionClient. www.kontron.com // 51...
  • Page 52: Figure 26: Wall/Panel Mounting Of The Fusionclient By Use Of The Mounting Clamps

    The maximum thickness of the wall/panel is 6 mm. Refer to Table 7 and Figure 25 for the wall/panel cutout dimensions or to the corresponding mechanical drawings for your FusionClient on our web site www.kontron.com. The system must be properly powered down and disconnected from the power source and peripherals.
  • Page 53: 6/ Starting Up

    [refer to Figure 27, Figure 13 or subsection 9.1.1 “(X1) Power Input Connector”]. Fasten the screws to secure the wires into the clamps of the plug terminal. Close the cover (Figure 27, pos. 2). www.kontron.com // 53...
  • Page 54: Connecting To Power

    The wires used for power connections must be clearly marked (+/-/grounding) to ensure that they will be proper connected to the DC connector of the FusionClient and to the main power source, corresponding the signals marked (refer to Figure 13). www.kontron.com // 54...
  • Page 55 Connect the other ends of the DC power wires to the connections of the DC main power supply. Pay attention to the polarity of the connections. Switch on the disconnecting device (circuit breaker) in order to apply voltage to the terminals of the power wires. www.kontron.com // 55...
  • Page 56: Ac Power Connection

    “15-30V DC”. Make sure the connector is securely locked in place. Connect the AC power cord to the AC/DC adapter. Plug the AC connector of the adapter into an AC wall outlet of the AC power source. www.kontron.com // 56...
  • Page 57: Operating System And Hardware Component Drivers

    (optional hardware components) yourself. You can download the relevant drivers for the installed hardware from our web site at www.kontron.com by selecting the product. Pay attention to the manufacturer specifications of the operating system and the integrated hardware components.
  • Page 58 FusionClient – User Guide (Rev. 1.3) www.kontron.com // 58...
  • Page 59: 7/ Maintenance And Cleaning

    Wet the glass plate with a microfiber cloth lightly moistened with warm water and mild glass cleaner. 7.2. Replacing the Lithium Battery The lithium battery is located on the installed carrier board and is not a serviceable part. Please contact Kontron support if the lithium battery needs to be replaced. www.kontron.com // 59...
  • Page 60: 8/ Technical Data

    Power LED LED Indicators (on the bottom side) Storage activity LED DC IN Power Plug 3 pin Phoenix connector On the bottom side (on the bottom side) Power DC: external 15-30 V power source (limited power source) www.kontron.com // 60...
  • Page 61 AC: via the optional external AC/DC adapter (limited power source) not included Lithium Battery (option) Type: CR2032; 3.0 V; 0.22Ah; VESA 75/100 On the rear IP20 rear Protection Class IP65 front (only mounted to a wall/panel) The table is continued on the next page. www.kontron.com // 61...
  • Page 62: Electrical Specifications

    EN 60950-1 to connect the FusionClient to an AC power source. FusionClient FC 121 FC 156 FC 185 FC 215 Power 15-30 V DC Power consumption 3.0 A max. 3.0 A max. 3.5 A max. 3.5 A max. www.kontron.com // 62...
  • Page 63: Mechanical Specifications

    FusionClient – User Guide (Rev. 1.3) 8.2. Mechanical Specifications For detailed mechanical dimensions, please see the outline dimensions drawings on the web site www.kontron.com. FusionClient FC 121 FC 156 FC 185 FC 215 Height 266 mm (10.47") 298 mm (11.73") 337 mm (13.27")
  • Page 64: Figure 28: Mechanical Specification - Front View Of The Fc 121

    FusionClient – User Guide (Rev. 1.3) Figure 28: Mechanical specification - Front view of the FC 121 Figure 29: Mechanical specification - Rear view of the FC 121 www.kontron.com // 64...
  • Page 65: Figure 30: Mechanical Specification - Side View Of The Fc 121

    FusionClient – User Guide (Rev. 1.3) Figure 30: Mechanical specification - Side view of the FC 121 www.kontron.com // 65...
  • Page 66: Figure 31: Mechanical Specification - Front View Of The Fc 156

    FusionClient – User Guide (Rev. 1.3) Figure 31: Mechanical specification - Front view of the FC 156 Figure 32: Mechanical specification - Rear view of the FC 156 www.kontron.com // 66...
  • Page 67: Figure 33: Mechanical Specification - Side View Of The Fc 156

    FusionClient – User Guide (Rev. 1.3) Figure 33: Mechanical specification - Side view of the FC 156 www.kontron.com // 67...
  • Page 68: Figure 34: Mechanical Specification - Front View Of The Fc 185

    FusionClient – User Guide (Rev. 1.3) Figure 34: Mechanical specification - Front view of the FC 185 Figure 35: Mechanical specification - Rear view of the FC 185 www.kontron.com // 68...
  • Page 69: Figure 36: Mechanical Specification - Side View Of The Fc 185

    FusionClient – User Guide (Rev. 1.3) Figure 36: Mechanical specification - Side view of the FC 185 www.kontron.com // 69...
  • Page 70 FusionClient – User Guide (Rev. 1.3) www.kontron.com // 70...
  • Page 71: Figure 37: Mechanical Specification - Front View Of The Fc 215

    FusionClient – User Guide (Rev. 1.3) Figure 37: Mechanical specification - Front view of the FC 215 Figure 38: Mechanical specification - Rear view of the FC 215 www.kontron.com // 71...
  • Page 72: Figure 39: Mechanical Specification - Side View Of The Fc 215

    FusionClient – User Guide (Rev. 1.3) Figure 39: Mechanical specification - Side view of the FC 215 www.kontron.com // 72...
  • Page 73: Environmental Specifications

    10 Hz to 500 Hz, 1G/3axes acc. to IEC 60068-2-6:2008-10 Vibration (non operating ) 10 Hz to 500 Hz, 2G/3axes acc. to IEC 60068-2-6:2008-10 Max. operation altitude 3,000 m (9842,52 ft.) Max. storage/transit altitude 4,572 m (15,000 ft.) www.kontron.com // 73...
  • Page 74: Ce-Directives, Standards And Approvals

    8.5. WiFi Specification (Option) WiFi Specification IEEE WLAN Standard 802.11a, 802.11b, 802.11g, 802.11n Interface USB 2.0 Antenna 2T2R 8.6. RFID Specification (Option) RFID Specification RFID Reader IDS-R13MP HF/13.56MHz ISO15693 Internal antenna Internal connected Read distance (d Peak) 0-20 mm www.kontron.com // 74...
  • Page 75: 9/ Standard Interfaces - Pin Assignments

    Lane 2 (n) Lane 3 (p) GND (ML Lane 3) Lane 3 (n) AUX SEL# Pull-down to GND AUX CH (p) GND (AUX CH) AUX CH (n) Hot Plug 3.3V (DDC EEPROM GND (GND_DDC) power 500 mA fused www.kontron.com // 75...
  • Page 76: Usb 2.0 Port (X5, X6)

    VCC, fused (900 mA max.) StdA_SSRX- Data- StdA_SSRX+ Data+ GND_DRAIN GND (ground for power StdA_SSTX- return) StdA_SSTX+ 9.1.6. Ethernet Connectors (X2, X3, X10) Pin# Signal Name X2, X3, X10LAN1, LAN2,LAN3 (RJ45) MDI0+ MDI0- MDI1+ MDI2+ MDI2- MDI1- MDI3+ MDI3- www.kontron.com // 76...
  • Page 77: Optional Interfaces

    Signal Name 9-pin D-SUB Plug (female) TxD- (Transmit Data-) RxD+ (Receive Data+) TxD+ (Transmit Data+) RxD- (Receive Data-) GND (Signal Ground) RTS- (Request to Send-) RTS+ (Request to Send+) CTS+ (Clear to Send+) CTS- (Clear to Send-) www.kontron.com // 77...
  • Page 78: X12) Serial Port (Rs422/Rs485) Configured As Rs485 (4-Wire Mode), Full Duplex, (Bus-Master)

    TxD- (Transmit Data-) RxD+ (Receive Data+) TxD+ (Transmit Data+) RxD- (Receive Data-) GND (Signal Ground) 9.2.4. (X12) Serial Port (RS422/RS485) configured as RS485 (2-Wire Mode), half duplex Signal Name 9-pin D-SUB Plug (female) Data- Data+ GND (Signal Ground) www.kontron.com // 78...
  • Page 79: 10/ Technical Support

    RMA No. e-mail: service@kontron.com Ensure that you have received an RMA number from Kontron Customer Services before returning any device. Write this number clearly on the outside of the package. Describe the fault that has occurred.
  • Page 80: About Kontron

    FusionClient – User Guide (Rev. 1.3) About Kontron Kontron is a global leader in embedded computing technology (ECT). As a part of technology group S&T Kontron offers a combined portfolio of secure hardware, middleware and services for Internet of Thing (IoT) and Industry 4.0 applications.