Trouble Criterion Of Main Parts - Mitsubishi Electric PEA-RP200WKA Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for PEA-RP200WKA:
Table of Contents

Advertisement

9-6. TROUBLE CRITERION OF MAIN PARTS

Part name
Room temperature
thermistor
(TH1)
Pipe temperature
thermistor/liquid
(TH2)
Condenser/evaporator
temperature thermistor
(TH5)
9-7. Thermistor
<Thermistor Characteristic graph>
Thermistor for
lower temperature
Thermistor R
=15k" ± 3%
0
Fixed number of B=3480k" ± 2%
Rt=15exp { 3480(
273+t
0:
15k"
10:
9.6k"
20:
6.3k"
25:
5.2k"
30:
4.3k"
40:
3.0k"
Check method and criterion
Measure the resistance with a tester.
(Part temperature 10°C ~ 30°C)
Normal
4.3kΩ~9.6kΩ
Room temperature thermistor (TH1)
Pipe temperature thermistor (TH2)
Condenser/evaporator temperature
thermistor (TH5)
1
1
) }
273
Abnormal
Opened or short-circuited
< Thermistor for lower temperature >
50
40
30
20
10
0
29
-20 -10 0
10 20 30 40 50
Temperature (:)