Technical description
6.3

Motor holding brake

A 24V / max.1.5A holding brake in the motor can be controlled directly by the amplifier.
Check voltage drop, measure the voltage at brake input and check brake function
(brake and no brake). This function does not ensure personnel safety!
The brake function must be enabled through the BRAKE setting (screen page: Motor). In
the diagram below you can see the timing and functional relationships between the
ENABLE signal, speed setpoint, speed and braking force. All values can be adjusted with
parameters, the values in the diagram are default vales.
During the internal ENABLE delay time of 100ms (DECDIS), the speed setpoint of the
servo amplifier is internally driven down an adjustable ramp to 0V. The output for the
brake is switched on when the speed has reached 5 rpm (VELO), at the latest after 5 sec-
onds (EMRGTO).
The rise (f
ferent for the various types of motor (see motor manual). A description of the interface
can be found on page 51. Operation of the brake in a manner that provides personnel
safety requires an additional "make" contact in the brake circuit, and a suppressor device,
such as a varistor, for the brake circuit.
Recommended circuit:
22
10/2007
) and fall (f
) times of the holding brake that is built into the motor are dif-
brH
brL
SERVOSTAR
®
SERVOSTAR
300 Product Manual
Danaher Motion