Expansion Module -2Can; Installation; Front View; Connection Technology - Danaher SERVOSTAR 300 Series Product Manual

Digital servo amplifier
Table of Contents

Advertisement

Expansions Cards
10.8

Expansion module -2CAN-

Connector X6 of the SERVOSTAR is assigned to the signals for the RS232 interface and
the CAN interface. It is therefore not the standard pin assignment for these interfaces,
and a special cable is required to be able to use both interfaces simultaneously.
The -2CAN- expansion module provides the interfaces on separate Sub-D connectors.
The two CAN connectors are wired in parallel. A termination resistor (120 W) for the CAN
bus can be switched into circuit if the SERVOSTAR is at the end of the bus.
10.8.1

Installation

The modul must be placed onto the option slot after levering off the cover of the option
slot and replacing the small cover (see p. 101):
l
l
l
l
10.8.2

Front view

10.8.3

Connection technology

Standard shielded cables can be used for the RS232 and CAN interfaces.
If the servo amplifier is the last device on the CAN bus, then the switch for the bus
termination must be set to ON.
Otherwise, the switch must be set to OFF (condition as delivered).
114
Screw the distance pieces into the fixing lugs of the option slot.
Place the expansion module onto the option slot.
Screw the screws into the threads of the distance pieces.
Plug the Sub-D9 socket into connector X6 on the SERVOSTAR