8
Execute Program Number 042 Press the Camera
Selection Button/Preset Position Button 4, 2 and 16
sequentially, the Menu as shown in Table 4-4 will be dis-
played.
SELF CHECK
042
H PHASE(R-2)
Table 4-4
8
Connect the terminated Oscilloscope with 75Ω to the
Recording Output Connector on the Rear Panel.
8
Adjust VR18 so that the Border signal level becomes 700
± 14 mV as shown in Fig. 4-5.
8
Adjust VR36 so that the Burst signal level becomes 300 ±
14 mV as shown in Fig. 4-5.
8
Confirm that the Sync signal level becomes 300 ± 30 mV
as shown in Fig. 4-5.
300 ± 14 mV
8
Press the Reset Button.
8
Change the connection of the terminated Oscilloscope
with 75Ω to the Multiscreen Output Connector on the Rear
Panel.
8
Execute Program Number 044 Press the Camera
Selection Button/Preset Position Button 4, 4 and 16
sequentially, the Menu as shown in Table 4-5 will be dis-
played.
SELF CHECK
044
H PHASE(M-2)
Table 4-5
8
Adjust VR20 so that the Border signal level becomes 700
± 14 mV as shown in Fig. 4-6.
00-0F
0C
700 ± 14 mV
300 ± 30 mV
Fig 4-5
00-0F
0C
8
Adjust VR35 so that the Burst signal level becomes 300 ±
14 mV as shown in Fig. 4-6.
8
Confirm that the Sync signal level becomes 300 ± 30 mV
as shown in Fig. 4-6.
300 ± 14 mV
8
Press the Reset Button.
(7). Y Pedestal, Y Gain, Chroma Gain and Chroma
Phase Adjustment
Test Point:
Recording Output Connector
Adjust:
VR25 (Y GAIN-0)
VR26 (Y GAIN-1)
VR27 (Y GAIN-2)
VR28 (Y GAIN-3)
VR29 (Y GAIN-4)
VR30 (Y GAIN-5)
VR31 (Y GAIN-6)
VR32 (Y GAIN-7)
VR33 (VBS Y GAIN)
VR22 (Y/C Y GAIN)
VR23 (Y/C C GAIN)
VR2 (C PHASE-0)
VR4 (C PHASE-1)
VR6 (C PHASE-2)
VR8 (C PHASE-3)
VR9 (C PHASE-4)
VR12 (C PHASE-5)
VR14 (C PHASE-6)
VR16 (C PHASE-7)
VR34 (C PHASE)
8
Supply the Ramp signal to the Camera Input Connectors
1, PLAY-IN Connector and S-Video Connector of the
Playback Input Connector on the Rear Panel.
Note : The supplied signals to the Camera Input
Connector 1 and S-Video Connector must be syn-
chronized.
8
Connect the terminated Oscilloscope with 75Ω to the
Recording Output Connector on the Rear Panel.
24
700 ± 14 mV
300 ± 30 mV
Fig 4-6
Rear Panel
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board

Advertisement

Table of Contents
loading

Table of Contents