Panasonic WJ-FS616 Service Manual page 12

Video multiplexer
Hide thumbs Also See for WJ-FS616:
Table of Contents

Advertisement

Setting the Termination and Controller
Unit Number
The Termination Switch and the Controller Unit Number
Switch are located on the rear of the System Controller.
When combined with the WJ-FS616 Video Multiplexer,
always keep these switches in the positions shown
below.
Connection with Alarm Sensors
Connect the sensor switches to the Alarm/Remote (ALARM/REMOTE) Control Connector on the rear of the Video Multiplexer
as shown in the example below.
ALARM/REMOTE
1
SW16
GND
SW2
SW1
19
TERM.
ON
OFF
Pin No.
1
Function
2
Electronic Zoom
3
Sequence
4
Spot
20
5
Alarm/Remote Select Input
6
Sequence SW for Spot Output
7
Not Used
8
Alarm Recover Input
9
Alarm Output
10
Alarm 16
11
Alarm 14
12
Ground
13
Alarm 11
14
Alarm 9
15
Alarm 8
16
Alarm 6
17
Ground
37
18
Alarm 3
19
Alarm 1
Setting the Mode Selection Switch
The Mode Selection Switch, that selects the operation
mode of the System Controller, is located on the rear of
the System Controller.
When combined with the WJ-FS616 Video Multiplexer,
always keep these switches in the positions shown
below.
0
MODE
OFF
ON
Designation
Pin No.
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
9
Designation
Still Picture
VTR/Camera Select
Multiscreen Select
Multiscreen
Ground
Alarm & SW Output
Time Adjust Input
Alarm Reset Output
Ground
Alarm 15
Alarm 13
Alarm 12
Alarm 10
Ground
Alarm 7
Alarm 5
Alarm 4
Alarm 2

Advertisement