Video
Output
Signal
TP73
(5). PLL DC Adjustment
Test Point:
TP28 (PLL DC-0)
TP30 (PLL DC-1)
TP32 (PLL DC-2)
TP34 (PLL DC-3)
TP37 (PLL DC-4)
TP38 (PLL DC-5)
TP41 (PLL DC-6)
TP42 (PLL DC-7)
Adjust:
L116 (PLL DC-0)
L117 (PLL DC-1)
L118 (PLL DC-2)
L119 (PLL DC-3)
L121 (PLL DC-4)
L122 (PLL DC-5)
L123 (PLL DC-6)
L124 (PLL DC-7)
8
Supply the Colour Bar signal to the Camera Input
Connectors 1 on the Rear Panel.
8
Turn the Power Switch off.
8
Turn the Power Switch on while pressing the Camera
Selection Buttons/Preset Position Buttons 5, 1 and 6 on
the Front Panel.
The Idle Menu will be displayed as shown in Table 4-1.
SELF CHECK
Table 4-1
8
Execute Program Number 042 Press the Camera
Selection Button/Preset Position Button 4, 2 and 16
sequentially, the Menu as shown in Table 4-2 will be dis-
played.
8H before the end
of Video signal
Fig 4-4
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
Switch Board
IDLE
042
H PHASE(R-2)
8
Connect the Digital Voltmeter to TP28.
8
Adjust L116 to obtain 2.0 ± 0.3 V DC.
8
Change the connection of the Digital Voltmeter to TP30.
8
Adjust L117 to obtain 2.0 ± 0.3 V DC.
8
Change the connection of the Digital Voltmeter to TP32.
8
Adjust L118 to obtain 2.0 ± 0.3 V DC.
8
Change the connection of the Digital Voltmeter to TP34.
8
Adjust L119 to obtain 2.0 ± 0.3 V DC.
8
Press the Reset Button.
8
Execute Program Number 044 Press the Camera
Selection Button/Preset Position Button 4, 4 and 16
sequentially, the Menu as shown in Table 4-3 will be dis-
played.
044
H PHASE(M-2)
8
Connect the Digital Voltmeter to TP37.
8
Adjust L121 to obtain 2.0 ± 0.3 V DC.
8
Change the connection of the Digital Voltmeter to TP38.
8
Adjust L122 to obtain 2.0 ± 0.3 V DC.
8
Change the connection of the Digital Voltmeter to TP41.
8
Adjust L123 to obtain 2.0 ± 0.3 V DC.
8
Change the connection of the Digital Voltmeter to TP42.
8
Adjust L124 to obtain 2.0 ± 0.3 V DC.
8
Press the Reset Button.
(6). Output Gain Adjustment
Test Point:
Recording Output Connector
Adjust:
VR18 (BORDER-1)
VR36 (BURST-1)
VR20 (BORDER-2)
VR35 (BURST-2)
8
Disconnect all signal from the Camera Input Connectors 1
on the Rear Panel.
23
SELF CHECK
00-0F
0C
Table 4-2
SELF CHECK
00-0F
0C
Table 4-3
Rear Panel
Switch Board
Switch Board
Switch Board