4 Technical data

Description
Storage volume (real) acc.
to DIN EN 12897
Max. working temperature
Min. working temperature
Max. working pressure
Max. rel. humidity
Max. env. temperature
Weight (empty)

5 Installation

All pipes connecting to the tank should have removable connections (fitting/flange). Pipe thread seals with teflon are to
be avoided.
All tank connecting pipes are to be planned, constructed and tested according to the technical rules in force, as well as to the
corresponding norms and regulations in accordance with their application and supply medium.
Sensors and thermostats necessary for temperature control must be securely and permanently positioned on the tank
(immersion sleeve and sensor rail).
The tank's venting and draining facilities must have the appropriate dimensions and be correctly installed.
The installation company is responsible for the correct execution of work and for the safe and careful insulation of the pipes.
All factory-made, non-insulated surfaces must be insulated in a professional manner on site.

6 Commissioning

Before putting into operation, the entire system should be flushed through. Particles in the system compromise the
operating reliability.
Fill the heating system slowly with water and vent all the air.
Start-up the system.
Before the handover of the system to the end user/owner, the plumbing contractor should ensure that the
system is tested to full load, controls are set and that pipe work and connections are without leaks. Afterwards,
the end user has to be instructed in the operation and handling of the tank, as well as the system. The instruction
must to be documented in the installation and maintenance record.
Please note that the operation and lifetime of the system depend decisively on a regular maintenance.

7 Maintenance and wear parts

Regular maintenance increases the lifetime and operation reliability of the system.
A damp cloth is sufficient to clean the outer parts. Please avoid using any abrasive or solvent cleaning.

8 Recycling and disposal

The products are specified and manufactured according to VDI 2243. The products are mechanically separable and 100%
recyclable. Make sure that the components are disposed according to the relevant regulations.
© Wikora GmbH
WKS
WKS
155
205
[litre]
153
201
50
[°C]
50
2
[°C]
2
[bar]
10
10
[%]
70
70
[°C]
24
24
[kg]
95
100
WKS
WKS
WKS
305
405
505
300
431
500
50
50
50
2
2
2
10
10
10
70
70
70
24
24
24
103
122
151
Page 4
WKS
WKS
WKS
805
1005
1505
830
983
1535
50
50
50
2
2
2
10
10
6
70
70
70
24
24
24
206
234
273
WKS
WKS
2005
3005
2010
3035
50
50
2
2
6
6
70
70
24
24
359
431
Chart 3
As of 8/25/2015