4 Technical data

Description
Storage volume (real) acc. to DIN EN 12897
Max. working temperature DHW / heating
Max. working pressure DHW / heating
Capacity of heat exchanger
Surface of heat exchanger
Flow rate of heat exchanger
Pressure drop of heat exchanger
Insulation
Performance DHW 45 °C / 90 °C
Performance DHW 60 °C / 90 °C
Max. performance of heat exchanger
Nominal Load N
(according to DIN 4708)
L
Standing loss
Energyefficiency class
Weight (empty)
© Wikora GmbH
WBL 150
WBL 200
[litre]
148
[°C]
95 / 130
95 / 130
[bar]
10 / 16
10 / 16
[litre]
5,0
[m²]
0,92
[m³/h]
2,3
[mbar]
80
PUR
[l/h (kW)]
800 (32,5) 990 (40,2)
[l/h (kW)]
475 (27,5) 595 (34,6)
[kW]
32,5
ca. 2,8
ca. 3,8
[Watt]
52
B
[kg]
ca. 124
ca. 155
Page 4
197
6,1
1,12
2,4
108
40,2
63
C
Chart 3