1
General ................................................................................................................................................................................... 2
2
Transport and installation ....................................................................................................................................................... 2
3
Dimensions and connections .................................................................................................................................................. 3
4
Technical data ........................................................................................................................................................................ 4
5
Installation .............................................................................................................................................................................. 4
6
Commissioning ....................................................................................................................................................................... 5
7
Maintenance and wear parts .................................................................................................................................................. 5
8
Warranties and guarantee ...................................................................................................................................................... 6
9
Installation record ................................................................................................................................................................... 7
© Wikora GmbH
Heating buffer tank
without heat exchanger
WPH 300 - 2000
Installation
and
undertaken by a specialist.
General terms and conditions of warranty state that
all installations must be carried out by a suitably
trained and qualified plumber who observes the
local norms and regulations.
The installation and maintenance record must
be entirely completed and the user has to be
instructed accordingly.
Efficient operation can only be guaranteed if the
instructions of this manual are followed.
Warranty does not cover any damage caused due
to non-observance of this manual and the technical
rules in force.
The system is to be checked annually by a
specialized company. In addition, occurring defects
must be repaired immediately.
This document should be handed over to the
client on completion of the installation.
.
Page 1
WIKORA GmbH
Friedrichstr. 9
89568 Hermaringen
Phone: (07322) 9605-0
Fax: (07322) 9605-30
email: contact@wikora.de
commissioning
must
As of March 2011
Errors excepted.
be

Advertisement

loading

Summary of Contents for WIKORA WPH 300

  • Page 1: Table Of Contents

    Fax: (07322) 9605-30 email: contact@wikora.de Installation manual Heating buffer tank Operating instructions without heat exchanger WPH 300 - 2000 Installation commissioning must undertaken by a specialist. General terms and conditions of warranty state that all installations must be carried out by a suitably trained and qualified plumber who observes the local norms and regulations.
  • Page 2: General

    1 General Depending on the type and design, WIKORA tanks are suitable for heating and / or storing DHW and / or heating water. The heating is achieved indirectly via heat generators, if applicable, from different heat sources. The maximum working pressure and working temperature can be found in the technical data.
  • Page 3: Dimensions And Connections

    3 Dimensions and connections Illustration Dimensions: Type [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] WPH 300 1550 1230 1230 1570 1100 WPH 400 1630 1300 1300 1650 1150 WPH 500 1960 1630 1630 1980 1450 WPH 750...
  • Page 4: Technical Data

    600 kW 900 kW 3,0 bar 56 kW 112 kW 224 kW 395 kW 678 kW 1017 kW Thread diameter (inch) ¾ Illustration 2 (Schematic drawing– example hydraulic system heating) © Wikora GmbH Page 4 As of March 2011 Errors excepted.
  • Page 5: Commissioning

    If there is a danger of freezing, the DHW tank should be permanently heated or completely emptied. A damp cloth is sufficient to clean the outer parts. Please avoid using any abrasive or solvent cleaning. © Wikora GmbH Page 5 As of March 2011 Errors excepted.
  • Page 6: Warranties And Guarantee

    2 years, free container replacement is guaranteed under condition that the anode has been examined annually and replaced after 2 years by an original Wikora anode (individual receipts needed) and - if proof of maintenance and the exchange of the anode is provided by a specialized company in accordance with our maintenance log.
  • Page 7: Installation Record

    In the case of reclamation, the receipts for maintenance must be provided as proof. Please complete the data sheet, including the reason for reclamation, and submit to Wikora. Submitting the maintenance record does not ensure any promise of guarantee or claim.

This manual is also suitable for:

Wph 2000