Technical Data; Installation - WIKORA WBO 1505 UNO Installation Manual Operating Instructions

Dhw storage tank
Table of Contents

Advertisement

4 Technical data

Description
Storage volume (real) acc. to DIN EN 12897
Max. working temperature DHW / Heating
Max. working pressure DHW / Heating
Capacity of heat exchanger lower / upper
Surface of heat exchanger lower / upper
Flow rate of heat exchanger lower / upper
Pressure drop of heat exchanger lower / upper
Insulation
Performance
DHW 80 °C / 60 °C / 10 °C upper heat exchanger
Standing loss
Energyefficiency class
Weight (empty)

5 Installation

All pipes connecting to the tank should have removable connections (fitting/flange). Pipe thread seals with teflon are
to be avoided.
All tank connecting pipes are to be planned, constructed and tested according to the technical rules in force, as well as to the
corresponding norms and regulations in accordance with their application and supply medium.
Appropriate filters should be used to prevent dirt or particles from entering the tanks. Moreover, the tank should be ensured
against pressure fluctuations and excess pressure through the installation of tested pressure reducing valves and safety
valves.
Sensors and thermostats necessary for temperature control must be securely and permanently positioned on the tank
(immersion sleeve and sensor rail).
The tank's venting and draining facilities must have the appropriate dimensions and be correctly installed.
The installation company is responsible for the correct execution of work and for the safe and careful insulation of the pipes.
When connecting to a solar plant, a temperature limiter is required and must be installed on site at the hot water outlet
in order to prevent scalding.
Connection Scheme
(according to DIN 1988)
HW
BF
Circlation
BR
SF
SR
CW
© Wikora GmbH
[litre]
[°C]
[bar]
[litre]
[m²]
[m³/h]
[mbar]
lower heat exchanger
[l/h (kW)]
[Watt]
[kg]
Water plug
Safety valve
Safety group according to
DIN 1988
Drian pipe
WBO 1505 UNO
WBO 1505 DUO
1529
1525
95/110
95/110/110
6/10/10
6/10/10
30,6/ -
30,6 / 16,7
3,7 / -
3,7 / 2,0
2,4 / -
2,4 / 2,4
50 / -
50 / 27
1145 (67)
1145 (67)
-
728 (48)
163
166
-
ca. 353
ca. 394
Connection Scheme
(according to DIN 1988)
HW
BF
Circulation
BR
CW
Page 4
WBO 1505 H
1520
95/110
6/10
75,5 / -
9,0 / -
2,4 / -
105 / -
120 mm Neopor/fleece
1934 (112)
-
163
-
-
ca. 446
water pipe
Safety valve
Safety group according to
DIN 1988
Drain pipe
Illustration 2 (Schematic diagram)
As of January 31, 2019
Errors excepted.
WBO 1505 WP/SOL
1517
95/110/110
6/10/10
30,6 / 60,5
3,7 / 7,0
2,4 / 2,4
24 / 44
1145 (67)
1703 (99)
166
-
ca. 473
Chart 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wbo 1505 duoWbo 1505 hWbo 1505 wp/sol

Table of Contents