1
General ................................................................................................................................................................................... 2
2
Transport and installation ....................................................................................................................................................... 2
3
Dimensions and connections .................................................................................................................................................. 3
4
Technical data ........................................................................................................................................................................ 4
5
Installation .............................................................................................................................................................................. 5
6
Commissioning ....................................................................................................................................................................... 6
7
Maintenance and wear parts .................................................................................................................................................. 6
8
Recycling and disposal ........................................................................................................................................................... 6
9
Warranties and guarantee ...................................................................................................................................................... 7
10
Installation record ................................................................................................................................................................... 8
© Wikora GmbH
DHW buffer tank
without heat exchanger
WPS 805 - 3005
Installation
and
undertaken by a specialist.
General terms and conditions of warranty state that
all installations must be carried out by a suitably
trained and qualified plumber who observes the
local norms and regulations.
The installation and maintenance record must
be entirely completed and the user has to be
instructed accordingly.
Efficient operation can only be guaranteed if the
instructions of this manual are followed.
Warranty does not cover any damage caused due
to non-observance of this manual and the technical
rules in force.
The system is to be checked annually by a
specialized company. In addition, occurring defects
must be repaired immediately.
This document should be handed over to the
client on completion of the installation.
.
Page 1
WIKORA GmbH
Friedrichstr. 9
89568 Hermaringen
Phone: (07322) 9605-0
Fax: (07322) 9605-30
email: contact@wikora.de
commissioning
must
As of February 1, 2019
Errors excepted.
be

Advertisement

Table of Contents
loading

Summary of Contents for WIKORA WPS 805

  • Page 1: Table Of Contents

    Fax: (07322) 9605-30 email: contact@wikora.de Installation manual DHW buffer tank Operating instructions without heat exchanger WPS 805 - 3005 Installation commissioning must undertaken by a specialist. General terms and conditions of warranty state that all installations must be carried out by a suitably trained and qualified plumber who observes the local norms and regulations.
  • Page 2: General

    1 General Depending on the type and design, WIKORA tanks are suitable for heating and / or storing DHW and / or heating water. The heating is achieved indirectly via heat generators, if applicable, from different heat sources. The maximum working pressure and working temperature can be found in the technical data.
  • Page 3: Dimensions And Connections

    3 Dimensions and connections Illustration 1 Dimensions: Type ∅ d [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] WPS 805 1540 1209 1880 1891 WPS 1005 1855 1446 2195 1135 2227 WPS 1505 1000 1240 1730 1315 2150...
  • Page 4: Technical Data

    4 Technical data Description WPS 805 WPS 1005 WPS 1505 WPS 2005 WPS 3005 Storage volume (real) acc. to DIN EN 12897 [litre] 1535 2010 3035 Max. working temperature [°C] Max. working pressure [bar] Insulation 100 mm Neopor/fleece 120 mm Neopor/fleece...
  • Page 5: Installation

    200 l NW 15 (1/2“) 75 kW above 200 to 1000 l NW 20 (3/4“) 150 kW above 1000 to 3000 l NW 25 (1“) 250 kW © Wikora GmbH Page 5 As of February 1, 2019 Errors excepted.
  • Page 6: Commissioning

    It should be examined for the first time after 2 years and afterwards annually in order to check its transmission. The diameter should be at least 1/3 of the original diameter, the surface should be homogenous and without any limescale crust. If necessary, it should be replaced by an original Wikora anode to protect the tank against corrosion.
  • Page 7: Warranties And Guarantee

    Under condition that the limits of the valid DHW regulations have been respected, the anode has been examined for the first time after 2 years and afterwards annually and that the anode has been replaced by an original Wikora anode (individual receipts needed) by a specialized company.