At+ Cdebyteiot; At+Ebtiot; At+Csq; At+Creg - Ebyte E840-DTU User Manual

Wireless
Hide thumbs Also See for E840-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co,;Ltd
Return: <CR><LF>+OK<CR><LF>
Para:
time
Short connection time 0 OFF, range 2~65535 seconds

AT+ CDEBYTEIOT

Function: Set/Query the IP and port address of the Ebyte IoT cloud platform.
Format:
Query
Send: AT+ CDEBYTEIOT<CR>
Return: <CR><LF>+OK=<ip>,<port><CR><LF>
Set
Send: AT+ CDEBYTEIOT=<ip>,<port><CR>
Return: <CR><LF>+OK<CR><LF>

AT+EBTIOT

Function: Set/Query Ebyte IoT platform.
Format:
Query
Send: AT+EBTIOT <CR>
Return: <CR><LF>+OK=<ctrl><CR><LF>
Set
Send: AT+EBTIOT =<ctrl><CR>
Return: <CR><LF>+OK<CR><LF>
Para:
ctrl Ebyte IoT platform switch ON Turn on / OFF Turn off
Note: After the IoT cloud function is enabled, the device is automatically connected to the Ebyte IoT platform,
ignoring

AT+CSQ

Function: Query signal strength.
Format:
Query
Send: AT+CSQ<CR><LF>
Return: <CR><LF>+OK=<csq><CR><LF>
Para:
csq signal strength
Note: None

AT+CREG

Function: Query whether to register to the operator network.
Format:
Query
Send: AT+CREG<CR><LF>
Return: <CR><LF>+OK=<creg><CR><LF>
Para:
creg

1 Registered to the network

0 Not registered to the network
Note: None

AT+CPIN

Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co,;Ltd
the sock configuration and registration packet, heartbeat packet function.
E840-DTU(NB-03) User Manual