CoolAir RTX1000, RTX2000
z The downward slope of the roof in forward direction in the area where
the unit is installed must not be more than:
– RTX1000: 8°
– RTX2000: 20°
z The assembly parts supplied must not be modified during installation.
z The ventilation openings must not be covered over (minimum distance
from other external attachments: 100 mm).
z Follow the vehicle manufacturer's guidelines when installing the
system and establishing the electrical connections.
I
NOTE
After installation of the system, the pre-set parameters on the system
software must be checked (chapter "Configuring the system software"
on page 13).
7.2
Creating the opening (if necessary)
I
NOTE
To simplify the task of creating the opening, there is a template
integrated in the packaging of the installation kit.
➤ Create an opening measuring 505 mm x 500 mm with rounded
corners with a radius of R25 (fig. 5, arrow = forward direction).
I
NOTE
Dispose of all waste materials separately. When doing so, follow the
waste disposal requirements applicable in your local area.
7.3
Removing the roof hatch
Proceed as follows (fig. 6):
➤ Remove all screws and fixings for the existing roof hatch.
➤ Take out the roof hatch.
➤ Remove the sealant around the opening so that the surface is clean
and free of grease.
I
NOTE
Dispose of all waste material, glue, silicon and seals separately. When
doing so, follow the waste disposal requirements applicable in your local
area.
EN
Installation
9