  • Page 1 OPERATING INSTRUCTIONS EFFICIENT • WARM • FRIENDLY...
  • Page 2 NECTRE INBUILT (MK2) Glen Dimplex Australia proudly supports the activities of Landcare Australia through its membership of the AHHA.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS USER INSTRUCTIONS MAINTENANCE AND SERVICING Introduction ......... . Replacment of Fire Bricks .
  • Page 4: User Instructions

    1.1. AIR CONTROLS USER INSTRUCTIONS The Nectre Inbuilt (MK2) has two air controls for controlling the fire. INTRODUCTION Top air slide: This allows air to enter the firebox from above the door where it is then drawn down into the base of the Before use of this appliance please read these instructions fire while keeping the glass clean.
  • Page 5: Using Appliance For The First Time

    LIGHTING THE FIRE Place firelighters and/or paper and dry kindling wood in the base of the firebox. Open both air controls: top air slide – pull spring handle all the way out (to the left) bottom air slide – slide spring handle across to the left USING APPLIANCE FOR THE FIRST Light the paper or firelighters.
  • Page 6: Low Heat Output

    BURNING TIPS 5.2. LOW HEAT OUTPUT The heat output of the appliance can be reduced by 6.1. FUEL QUALITY closing the top air slide (slide to the right) which will restrict Use wood with a moisture content of less than 20%. Logs the oxygen supplied to the fire thereby slowing down the should not feel moist or damp, or have moss and fungal rate at which the wood burns.
  • Page 7: Ash Removal

    CLEANING THE FLUE Factors affecting the flue draught include: ● Check inside of flue prior to each season for any build-up Insufficient flue height of creosote (wood tar). To do this: ● Trees or other buildings nearby causing turbulence First remove the baffle (refer to “2. Replacement of ●...
  • Page 8: Troubleshooting Tips

    TROUBLESHOOTING TIPS MAINTENANCE AND SERVICING 11.1. GLASS IN DOOR BLACKENING This can have several possible causes: REPLACMENT OF FIRE BRICKS ● Burning unseasoned wood — if the wood is too wet, The purpose of the firebricks in the appliance is to increase it will cause the glass to blacken.
  • Page 9: Fitting New Door Glass

    FITTING NEW DOOR GLASS To remove the baffle: This task may be easier with the door removed from the Firebricks need to be removed before the baffle appliance and laid horizontally on a work-bench. plate can be removed (refer to “1. Replacment of Fire Bricks”...
  • Page 10: Fitting A New Door Seal

    FITTING A NEW DOOR SEAL CHANGE FAN CONTROLLER FREQUENCY This task may be easier with the door removed from the appliance and laid horizontally on a work-bench. The frequency used by the fan remote control can be changed if interferences are experienced in the home. Remove any old seal from the door.
  • Page 11: Fan Controller

    6.2. FAN CONTROLLER PART DETAIL Remove the battery cover and batteries. With a small Fan Remote screwdriver or equivalent, change the switch setting to be 3 speed Receiver the same as that on the remote control receiver. Fan Remote 3 speed Control Replace the batteries and cover, plug in the power lead and test the fan with the different frequency setting.
  • Page 12 Glen Dimplex Australia Pty Ltd 1340 Ferntree Gully Road, Scoresby Victoria 3179 Australia T: 1300 556 816 | F: 1800 058 900 Email: sales@glendimplex.com.au www.glendimplex.com.au...

This manual is also suitable for:

Inbuilt mk2