Gas connection

The appliance must be connected in accordance with the
currently applicable regulations. Before installing the appliance,
check that the local conditions (type of gas and pressure) are
compatible with the appliance settings. The conditions for
setting the appliance can be found on the rating plate.
Connection to the gas lines and seal fitting must be carried out
professionally according to the currently applicable standards.

Gas connection on the appliance

The gas connection (ISO 228-1, 1/2") is located at the rear left
of the appliance. The following connections are provided with
the appliance:
Connecting piece ISO 228-1/ISO
7-1 (with seal)
LPG corrugated tube union (with
seal)

Default setting of the burners

The burners are set up for G30 liquefied gas (29 mbar) on
delivery. A nozzle set for G20 natural gas (20 mbar) is supplied
with the appliance.

Connecting to natural gas

Only use connecting lines or flexible hoses which comply with
the applicable regulations and which are approved for this
purpose.
Screw the connecting piece ISO 7-1 (C) and the seal (B) to
1.
the gas connection (A).
Hold the connecting piece (C) with a spanner and screw it to
2.
a fixed connecting line (D) or a flexible gas connecting hose.
Only use approved sealing compound to seal the thread.
30
$
%
&
'

Connecting to liquefied gas

If you connect the appliance to liquefied gas, you must always
install a suitable gas pressure regulator. Use the total gas
consumption of the appliance stated on the rating plate to
select a suitable gas pressure regulator.
Only use connecting lines or flexible hoses which comply with
the applicable regulations and which are approved for this
purpose.
Screw the corrugated tube union (C) and the seal (B) to the
1.
gas connection (A).
Slide a flexible gas connecting hose onto the corrugated tube
2.
union (C).

Flexible hose

If you use flexible hoses, make sure that:
the hoses do not become trapped or squashed.
the hoses are not subject to twisting or pulling forces.
the hoses, for example, do not come into contact with sharp
edges or cutting edges.
the hoses do not come into contact with parts that could
reach a temperature higher than 70 °C above room
temperature.
Make sure that the full length of the hoses is accessible for
inspection.

Installing the safety valve

The installation of a safety valve for opening and closing the
gas supply is a compulsory requirement. Fit the safety valve
between the gas supply line to the appropriate room and the
appliance. Ensure unhindered access to this valve.

Checking for leaks

After connecting the gas line, check the connections for leaks
using soapy water.

Initial use

Switch the appliance on as described in the instructions for
use. Light all the burners and check that the flames remain
stable at both the high and low settings.
$
%
&