Installation Requirements

Comply with the valid national regulations for installation sites and electrical connections.

Installation Sites

Ventilation of the installation sites must be appropriate for device output. Inadequate ventilation of the
device will result in its overheating and being destroyed.

Electrical Connections

A socket outlet with an earthing contact featuring a maximum protection of 16 amps is required.Please
take care, that the socket for the unit is always accessible.
The line voltage must always be within following tolerances: 230 VAC +6%/-10% / 50 Hz

Installation

The device must be installed by a trained service technician.
Please take care, that the socket for the unit is always
accessible. There is no user serviceable items inside the
equipment.
If the power supply cable to the unit is damaged, it has to be replaced by the manufacturer, the service
partner or any other qualified person to avoid safety hazard.

Water Connection

Connecting only to drinkable water
Connect the device to a feed line with an inner diameter of min. 8 mm. We recommend using a water
filter and a water pressure regulator for the water input. To permit flushing of the filter, a T-piece
should be mounted downstream of the water pressure regulator. The water flow pressure should be 2
bar (mount control pressure gauge on water pressure regulator). In case of falling below the unit
switches off and switches on again having reached 2 bar of water pressure.
CO
Connection
2
You will require a singel-wire pressure regulator, 7 bar. Using tubing with an inner diameter of 4 mm,
connect the pressure regulator to the carbonator.

Connecting Soda Water and Still Water

Connect one tube with an inner diameter of 6 mm to each device connection. Connect the tube end to
the correct cooling coil inputs of the cooler.

Pump Control

Still Water Control at the Carbonator
For still water, one switching cable (1 x 0.75 mm
carbonator to the still water valve. The electronic control system is actuated via this cable. An addition
cable from one of the still water valves is necessery. Refer to the circuit diagram for the connection.
The flow rate of the still water has to be adjusted by the water pressure regulator and should be 170 ml
in 4 to 5 seconds.
Cornelius Deutschland GmbH
Document no/ Dokumenten-Nr.: TD22022600ML
Version A, 11.05.2020, Index 0
Balance Carbonator / Balance Karbonator
2)
per still water valve must run from the soda circuit
Manual operation / Gebrauchsanweisung
Carbonator/Karbonator HS/HK
Seite 9