11.1.5.2
Remote Controller Wiring
Remote Controller cable shall be (2 x min 0.3 mm
Total cable length shall be 50 m or less.
Be careful not to connect cables to other terminals (e.g. power source wiring terminal). Malfunction may occur.
Do not bundle together with the power source wiring or store in the same metal tube. Operation error may occur.
11.1.5.3
Mounting The Remote Controller
For exposed type
Preparation: Make 2 holes for screws using a driver.
Mono bloc unit
Remote Controller
wiring (field supply)
No polarity
Terminal for Remote Controller wiring
2
), of double insulation PVC-sheathed or rubber sheathed cable.
Mount the top case.
Align the claws of the top
case and then align the claws
of the bottom case.
Cut here with
a nipper and
remove the burr
with a file.
Claw (2 places)
Screw
(field supply)
Connect the remote control
wiring
Arrange the wires along the groove
of the case.
61
Remote Controller
1
2
Mount the bottom case to
the wall.
U P
Wall to which
the remote
controller is
fixed
Hole for screw
Claw (2 places)