Panasonic WH-MDC05H3E5 Service Manual page 16

Air-to-water, mono bloc unit
Hide thumbs Also See for WH-MDC05H3E5:
Table of Contents

Advertisement

Floor heating + Radiator
Mono bloc
or
Connect floor heating or radiator to 2 circuits through buffer tank as shown in figure.
Install pumps and thermistors (specified by Panasonic) on both circuits.
Install mixing valve in the circuit with lower temperature among the 2 circuits.
(Generally, if install floor heating and radiator circuit at 2 zones, install mixing valve in floor heating circuit.)
For temperature setting, select circulation water temperature for both circuits.
Both circuits can set circulation water temperature independently.
Install buffer tank thermistor on buffer tank.
It requires connection setting of buffer tank and ∆T temperature setting at heating operation separately.
This system requires the optional PCB (CZ-NS4P).
Mind that if there is no mixing valve at the secondary side, the circulation water temperature may get higher than
setting temperature.
Floor heating + Swimming pool
Mono bloc
or
Connect floor heating and swimming pool to 2 circuits through buffer tank as shown in figure.
Install mixing valves, pumps and thermistors (specified by Panasonic) on both circuits.
Then, install additional pool heat exchanger, pool pump and pool sensor on pool circuit.
Install the remote controller in room where floor heating is installed. Circulation water temperature of floor heating
and swimming pool can be set independently.
Install buffer tank sensor on buffer tank.
It requires connection setting of buffer tank and ∆T temperature setting at heating operation separately. This system
requires the optional PCB (CZ-NS4P).
Must connect swimming pool to "Zone 2".
If it is connected to swimming pool, operation of pool will stop when "Cooling" is operated.
Mono bloc
Buffer tank
Mono bloc
Mixing
valve 1
Buffer tank
Radiator
Pump 2
Thermistor 2
Pump 1
Mixing valve 1
Thermistor 1
Floor heating
Thermistor 3
Mixing
Thermistor 2
valve 2
Pump 1
Pump 2
Thermistor 1
Heat EXT
Floor heating 1
68
Setting of remote controller
Installer setting
System setup
Optional PCB connectivity - Yes
Zone and Sensor - 2 Zone system
Zone 1:Sensor
Water temperature
Zone 2:Sensor
Room
Setting of remote controller
Installer setting
System setup
Pump 3
Optional PCB connectivity - Yes
Zone and Sensor - 2 Zone system
Zone 1:Sensor
Room thermostat
Zone 2
Swimming pool
Swimming pool
Water temperature
Internal
T

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-mdc07h3e5Wh-mdc09h3e5

Table of Contents