Panasonic WH-MDC05H3E5 Service Manual page 21

Air-to-water, mono bloc unit
Hide thumbs Also See for WH-MDC05H3E5:
Table of Contents

Advertisement

11.3 How to Fix External Device
11.3.1
Connecting Cables Length
When connecting cables between Mono bloc and
external devices, the length of the said cables must
not exceed the maximum length as shown in the table.
External device
Two-way valve
Three-way valve
Mixing valve
Room thermostat
Booster heater
Extra pump
Solar pump
Pool pump
Pump
Boiler contact
External control
Tank sensor
Room sensor
Outdoor air sensor
Tank OLP
Buffer tank sensor
Pool water sensor
Solar sensor
Water sensor
Demand signal
SG signal
Heat/Cool switch
External compressor switch
11.3.1.1
Connection of the main PCB
C O N C O N
2-way
3-way
valve
valve
 Signal inputs
L N =AC230V, Heat, Cool=Thermostat heat, Cool
Optional
terminal
Thermostat
❈It does not function when using the optional PCB
Dry contact Vcc-Bit1, Vcc-Bit2 open/short (System
OLP for
setup necessary)
booster
It is connected to the safety device (OLP) of DHW
heater
tank.
Dry contact Open=not operate, Short=operate
External
(System setup necessary)
control
Able to turn ON/OFF the operation by external
switch
Connected (Please use 2 cores wire for relocation
Remote
and extension. Total cable length shall be 50m or
controller
less.)
Maximum cables length (m)
50
50
50
50
50
50
50
50
50
50
50
30
30
30
30
30
30
30
30
50
50
50
50
OLP for booster
heater
Zone 1 room sensor
Outdoor air sensor
Tank sensor
External control
Remote controller
Boiler contact
Extra pump
Booster heater
H C N L
Optional
Thermostat 1
 Outputs
AC230V N=Neutral Open, Close=direction (For
3-way valve
circuit switching when connected to DHW tank)
AC230V N=Neutral Open, Close (Prevent water
2-way valve
circuit pass through during cooling mode)
AC230V (Used when Mono bloc pump capacity is
Extra pump
insufficient)
Booster
AC230V (Used when using booster heater in DHW
heater
tank)
Boiler
Dry contact (System setup necessary)
contact
 Thermistor inputs
Zone 1 room
PAW-A2W-TSRT
sensor
the optional PCB
Outdoor air
AW-A2W-TSOD (Total cable length shall be 30m or
sensor
less)
Tank sensor Please use Panasonic specified part
11.3.1.2
Connection of Optional PCB
(CZ-NS4P)
Optional
Thermostat 2
L
N Cool Heat L
Pool
Pump
Solar
Pump
Error
signal
Zone 1
Pump
Zone 2
Pump
Zone 2
room
sensor
 Signal inputs
Optional
L N =AC230V, Heat, Cool=Thermostat heat, Cool
Thermostat
terminal
Dry contact Vcc-Bit1, Vcc-Bit2 open/short (System
setup necessary)
SG signal
Switching SW (Please connect to the 2 contacts
controller)
Heat/Cool
Dry contact Open=Heat, Short=Cool (System setup
SW
necessary)
External
Dry contact Open=Comp.ON, Short=Comp.OFF
comp.SW
(System setup necessary)
Demand
DC 0~10V (System setup necessary)
signal
Please connect to the DC 0~10V controller.
 Outputs
AC230V N=Neutral Open, Close=mixture
Mixing valve
direction
Operating time: 30s~120s
Pool pump
AC230V
Solar pump
AC230V
Zone pump
AC230V
heater
73
❈It does not work when using
Optional
Mixing
Mixing
Thermostat 1
valve 1
valve 2
N Cool Heat
N
O
C
N
O
Zone 1
Buffer
Pool
Zone 2
Zone 1
Demand
Solar
sensor
room
Tank
water
water
water
signal
sensor
sensor
sensor
sensor
sensor
C
Ext.
comp.
SW
Heat/
Cool
SW
Vcc
SG
Bit1
signal
Bit2

Advertisement