11.2 Variation of system

This section introduces variation of various systems using Air-To-Water Heatpump and actual setting method.
11.2.1
Introduce application related to temperature setting.
11.2.1.1
Temperature setting variation for heating
1. Remote Controller
Mono bloc
Connect floor heating or radiator directly to the Mono bloc.
This is the basic form of the most simple system.
2. Room Thermostat
Mono bloc
Connect floor heating or radiator directly to the Mono bloc.
Install the remote controller in the room where floor heating is installed.
This is an application that uses remote controller as Room Thermostat.
3. External Room Thermostat
Mono bloc
Connect floor heating or radiator directly to Mono bloc.
Install separate external Room Thermostat (field supply) in the room where floor heating is installed.
This is an application that uses external Room Thermostat.
Mono bloc
or
Mono bloc receive Room Thermo signal
(ON/OFF) from Remote controller to
control HP and circulation pump.
There is a build-in thermistor in the
remote controller.
Mono bloc
or
Mono bloc
or
Floor heating
Floor heating
Room
thermostat
(Field supply)
Floor heating
66
Setting of remote controller
Installer setting
System setup
Optional PCB connectivity - No
Zone & Sensor:
Water temperature
Setting of remote controller
Installer setting
System setup
Optional PCB connectivity - No
Zone & Sensor:
Room thermostat
Internal
Setting of remote controller
Installer setting
System setup
Optional PCB connectivity - No
Zone & Sensor:
Room thermostat
(External)