MODEL 188 & T188 SERIES SERVICE MANUAL
16-33. TROUBLE SHOOTING THE ALTERNATOR SYSTEM (14 VOLT SYSTEM)( Cont.)
TROUBLE
PROBABLE CAUSE
REMEDY
ALTERNATOR SYSTEM
Regulator faulty or improp-
2.
Stop engine, remove cowl,
WILL NOT KEEP BAT-
erly adjusted. (Cont.)
and remove cover from voltage
TERY CHARGED (Cont).
regulator.
Turn master switch
ON/OFF several times and ob-
serve field relay in regulator.
Relay should open and close with
master switch and small arc
should be seen as contacts open.
If relay is inoperative, proceed
to step 3. If relay operates,
proceed to step 4.
3. Check voltage at "S" terminal
of regulator with master switch
closed.
Meter should indicate bus
voltage.
If voltage is present, re-
place regulator.
If voltage is not
present, check wiring between
CAUTION
regulator and bus.
Before performing step 4, remove radios from the panel.
4.
Remove plug from regulator
and start engine.
Momentarily
jumper the "A+" and "F" termi-
nals together on the plug. Ship's
ammeter should show heavy rate,
of charge.
If heavy charge rate
is observed, replace regulator.
If heavy charge rate is not ob-
served, proceed to step 5.
Faulty wiring between alter-
5. Check resistance from "F"
nator and regulator, or
terminal of regulator to "F" ter-
faulty alternator.
minal of alternator.
Normal
indication is a very low resis-
tance.
If reading indicates no,
or poor continuity, repair or
replace wiring from regulator
to alternator.
6.
Check resistance from "F"
terminal of alternator to alter-
nator case.
Normal indication
is 6-7 ohms.
If resistance is
high or low. repair or replace
alternator.
7.
Check resistance from case
of alternator to airframe ground.
Normal indication is very low
resistance.
If reading indicates
no, or poor continuity, repair or
replace alternator ground wiring.
16-23