4.1.4
Important Receiving Instructions
Visually inspect all components for shipping damage. Shipping damage is not covered by warranty. If
shipping damage is found, notify carrier at once. The carrier is responsible for all repair and replacement cost
resulting from damage in shipment.
Note: Personnel should read this and associated puller unit manuals prior to use. Operators should be
trained on the contents of this manual prior to use.
4.1.5
Hydraulic Reservoir Breather
A shipping plug is installed in the breather port on the top of the reservoir. Before using the pump, replace the
shipping plug with the adaptor fitting and breather.
4.1.6
Hydraulic Connections
To ensure proper operation, avoid kinking or tightly bending hoses. If a hose becomes kinked or otherwise
damaged, it must be replaced. Damaged hoses may rupture at high pressure. Serious personal injury may
result.
Installation of a pressure gauge in each hydraulic line is strongly recommended. All hoses and fitting must be
rated to at least 10,000 psi [700 bar].
4.1.7
Battery Capacity Indicator
New Batteries should be charged before use. Each battery contains four indicator lights. The battery capacity
indicator lights show the approximate battery capacity level.
Press the battery capacity indicator button to display the lights. The battery capacity indicator light will stay
lit for two seconds after the button is pressed. Refer to Figure 4.1-2 to determine the level of charge.
Run time between battery charges is dependent on the application, pump run time, pressure setting and other
factors.
If none of the battery capacity indicator lights illuminate when the battery capacity is pressed, place the
battery on the charger and charge as needed.
When Battery Capacity Indicator
Fatigue Technology
401 Andover Park East
830959-REV A
Figure 4.1-2
Battery Capacity Indicator
Button is pressed:
4 Lights ON
3 Lights ON
2 Lights ON
1 Light ON
0 Lights ON
Seattle, WA • USA 98188-7605
Percent Charge:
(approximate)
80 - 100%
60 - 80%
40 - 60%
25 - 40%
< 25%
Tel: (206)246-2010
Fax: (206)244-9886