Advertisement

®
Black Box Corporation
The Source for Connectivity
®
© Copyright 1996. Black Box Corporation. All rights reserved.
P.O. Box 12800
Pittsburgh, PA 15241
(412) 746-5500
Fax (412) 746-0746

Advertisement

Table of Contents
loading

Summary of Contents for Black Box COS-2

  • Page 1 ® Black Box Corporation The Source for Connectivity ® © Copyright 1996. Black Box Corporation. All rights reserved. P.O. Box 12800 • Pittsburgh, PA 15241 • (412) 746-5500 • Fax (412) 746-0746...
  • Page 2 FCC AND DOC/MDC STATEMENTS FEDERAL COMMUNICATIONS COMMISSION CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication.
  • Page 3 HIGH SPEED COS-2 NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
  • Page 4 NOM STATEMENT 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.
  • Page 5: Table Of Contents

    HIGH SPEED COS-2 Contents Chapter Page 1. Specifications ..................7 2. Introduction ..................9 3. Configuration ..................10 3.1 Selecting the Operating Mode ........... 10 3.2 Setting Communication Parameters ........... 10 3.3 Choosing an Arming Code ............10 4. Installation ..................20 4.1 Placement and Mounting ............
  • Page 6: Specifications

    CHAPTER 1: Specifications 1. Specifications FCC Class A, DOC Class/MDC classe A Compliance — EIA RS-232 serial (all ports DCE) Interface — Asynchronous Protocol — Either 7 data bits with odd or even parity or 8 data Data Formats — bits with no parity (user-selectable);...
  • Page 7 HIGH SPEED COS-2 SW284A: Power — From wallmount power supply PS115: Input: 115 VAC, 60 Hz; Output: 9 VDC, 200 mA; SW284AE: From desktop power supply PS115E: Input: 230 VAC, 50 Hz; Output: 9 VDC, 200 mA 100,000 hours MTBF —...
  • Page 8: Introduction

    “arming code” (the code that causes the COS-2 to switch). As you can see, the COS-2 is very light and compact. For this reason, we’ve included a hook-and-loop fastener that you can use to attach the unit directly to any number of surfaces, including the housings of PCs and printers.
  • Page 9: Configuration

    3.2 Setting Communication Parameters Use the right-hand DIP switch on the bottom of the High-Speed COS-2 to set the COS-2’s communication parameters. As shown in Table 3-1 on page 12, positions 1 through 3 control the data rate; positions 4 and 5 control the data format;...
  • Page 10 CHAPTER 3: Configuration Port Mode Indicators Switch Mode Indicators Port A Master Power Switch Port B Power Jack Port C Baud Rate Parameters Switch Arming Code Switch Figure 3-1. Layout of the High Speed COS-2’s connectors, controls, and indicators.
  • Page 11 HIGH SPEED COS-2 Table 3-1. Possible Settings of the Communications DIP Switch* FUNCTION DIP SWITCH POSITIONS Data Rate (bps) 115,200 OFF OFF OFF 57,600 OFF OFF 38,400 19,200† 9600 OFF OFF 2400 1200 Data Format 8 data bits, no parity†...
  • Page 12 CHAPTER 3: Configuration Table 3-2. Possible Settings of the Arming-Code DIP Switch* ARMING CODE DIP SWITCH POSITIONS HEX ASCII NAME CTRL-@ NUL CTRL-A CTRL-B CTRL-C 04† CTRL-D CTRL-E CTRL-F CTRL-G CTRL-H CTRL-I CTRL-J CTRL-K CTRL-L CTRL-M CTRL-N CTRL-O CTRL-P CTRL-Q CTRL-R CTRL-S CTRL-T...
  • Page 13 HIGH SPEED COS-2 ARMING CODE DIP SWITCH POSITIONS HEX ASCII " & < >...
  • Page 14 CHAPTER 3: Configuration ARMING CODE DIP SWITCH POSITIONS HEX ASCII...
  • Page 15 HIGH SPEED COS-2 ARMING CODE DIP SWITCH POSITIONS HEX ASCII...
  • Page 16 CHAPTER 3: Configuration ARMING CODE DIP SWITCH POSITIONS HEX ASCII...
  • Page 17 HIGH SPEED COS-2 ARMING CODE DIP SWITCH POSITIONS HEX ASCII...
  • Page 18 CHAPTER 3: Configuration ARMING CODE DIP SWITCH POSITIONS HEX ASCII...
  • Page 19: Installation

    It should be within 50 ft. (15.2 m) of the devices you want to connect to it. Your package also includes a special “hook-and-loop fastener” fabric strip that allows you to mount the COS-2 in a convenient place, such as on a PC (see Figure 4-1 below). To mount the COS-2, remove the white backing of this strip, then attach the side with the “hooked”...
  • Page 20: Cabling

    “source” or “master” (the one that’s doing the switching), connect the male end of the cable to the COS-2’s port “A.” If the computer is a “destination” or “slave” (one that’s being switched), connect the male end of the cable to the COS-2’s port “B”...
  • Page 21 *Our EVNBMC cable is pinned this way. It also carries the other pins supported by the AT serial interface, but the High Speed COS-2 doesn’t support any of the other pins except Pin 1, PGND, which is not required, and the pins for DSR and RLSD (DCD), which the COS-2 ties high.
  • Page 22 *Our EYN254C cable is pinned this way. It also carries Pin 1, PGND, which the High Speed COS-2 supports but doesn’t require, as well as Pins 6 and 8 (DSR and RLSD [DCD] respectively, tied into the CTS DTR lines), which the COS-2 keeps tied high.
  • Page 23: Power Connection

    Lastly, plug the output cord of the High Speed COS-2’s power-supply adapter into the power socket (barrel jack) on the COS-2, then plug the adapter into a working outlet.
  • Page 24: Operation

    Turn on power to the High Speed COS-2 using the OFF/ON slide switch on its front panel (see Figure 3-1 on page 11). If position 6 of the COS-2’s right-hand DIP switch is set to OFF (down), the COS-2 will be ready to operate normally.
  • Page 25: The Self-Test

    HIGH SPEED COS-2 5.3 The Self-Test To have the High Speed COS-2 perform a quick self-test, turn it off and set position 6 of its right-hand DIP switch to ON (up). Connect port “B” to a terminal or other RS-232 device whose data rate and data format match those selected on the COS-2.
  • Page 26: Troubleshooting

    6.1 First Steps If the High Speed COS-2 does not seem to be passing data or switching correctly, the first thing to try is to have the COS-2 perform its self-test as described in . If the LEDs fail to light, contact your supplier. If Section 5.3...
  • Page 27: Shipping And Packaging

    HIGH SPEED COS-2 6.3 Shipping and Packaging If you need to transport or ship your High Speed COS-2: • Package it carefully. We recommend that you use the original container. • Before you ship a unit for repair or return, contact your supplier to get a Return Materials Authorization (RMA) number, and make sure you include everything you received with the unit when you ship it.
  • Page 28 NOTES...
  • Page 29 NOTES...
  • Page 30 Call our Technical Support Specialists to discuss your application. For 24-hour technical support: Call (412) 746-5500 or fax 1-800-321-0746 SUPPORT To order: Call (412) 746-5500, 8:00 A.M. to 8:00 P.M. EST INFORMATION Mail order: Black Box Corporation, P.O. Box 12800, Pittsburgh, PA 15241...

Table of Contents