Standby
Pressing the power switch for 5 seconds will turn the unit on or into standby. When in standby the display will
show
.
Accessing the Info Menu
Press and immediately release the ' ' button then using the
and
buttons select the data you wish to dis-
play the value of. When at the desired point press and hold the ' ' button to display the value.
Press the
button or leave the controller for 30 seconds and the unit will exit the 'Info' menu and resume
displaying the current temperature.
Set Point
To amend the set point press and hold the ' ' button for half a second. Then while keeping the ' ' button pressed
use the
and
buttons to set the desired value.
When the ' ' button is released the new value will be stored automatically.
Keypad Security Settings
This function avoids unauthorised controller access.
Press & release ' ' then use
to select '
'. Press and hold ' ' to change from '
' to '
'. Leave for 10
seconds or briefly press
to resume.
Internal Light (where fitted)
The on/off switch is located on the front of the light fitting.
Shelves, Supports & Drawers
Shelves - 'H' models are supplied with slotted removable shelf supports.
The only 'L' models that have fixed shelves that are part of the freezer system and cannot be removed are
the LR150-A & XR415L, all other 'L' models have removable shelves.
Refrigerated Drawers - can be removed by pulling out to their full extent and lifting so that the roller passes
through the slots in the drawer runner. Please ensure drawers are refit to their original position.
Food
Cover all foods and separate raw and cooked foods to avoid cross contamination.
Loading and Airflow
Each shelf or drawer is capable of holding up to 25kg of product evenly distributed
Always ensure the air can circulate around/through the stored product.
It is important that for optimal energy performance that adequate airflow is maintained around the perimeter
of the shelves, and around all stored products.
On all models please ensure that no product is placed on the unit base.
Door Lock (Where Fitted)
To lock the door insert the key and turn 90°, turn in the opposite direction to unlock.