5. REC C/AFM Current Adjustment

5-1. Preparations

Note 1: Check that the data of page: 0, address: 10 is "00".
Order Page Address Data
1
2
3
0
4
C
5
A
6
7
7
A
8
A
Note 2: Don't disconnect the DC power supply of camcoder dur-
ing the following adjustments.
When the following symptom occurs, reset the data of A
page to the values note down.
1) The power is shut off so that unit can not operate.
CCD-TRV138/TRV238E/TRV338/TRV438E
Procedure
Close the cassette compartment
without inserting cassette.
Set to the VTR stop mode.
01
01
14
01
Press PAUSE button.
10
10
Press PAUSE button.
10
02
Press PAUSE button.
1A
Note down the data.
Set the following data, and
press PAUSE button.
1A
06: NTSC model
26: PAL model

5-2. REC C Current Check (VC-341 Board)

Check the recording current level of the REC chroma signal.
If it is too low, chroma signal noise in playback picture will be
increased. If too high, Y signal noises will increase and white
modulation noises will be produced.
Mode
Signal
Measurement Point
Measuring Instrument
Specified value
Note 1: Check that the data of page: 0, address: 10 is "00".
Checking method:
Order Page Address Data
1
2
3
0
01
4
3
91
5
3
92
6
C
25
7
C
25
8
3
01
9
10
3
01
11
C
25
12
3
91
13
3
92
14
0
01
15
Note 2: Use the REC buttons of the adjustment remote com-
mander (with HOLD switch set in the OFF position).
A
6-33
VTR recording (PLAY/EDIT mode)
No signal
REC RF (Pin 7 of CN007)
Oscilloscope
(20 MHz BW LIMIT: OFF)
A = 50.8 ± 3.0 mVp-p (NTSC)
A = 54.0 ± 3.0 mVp-p (PAL)
Procedure
Close the cassette compartment
without inserting cassette.
Set to the VTR recording
mode. (Note 2)
01
30
20
Note down the data.
00
Press PAUSE button.
41
Press PAUSE button.
Check that the REC chroma
signal level (A) satisfies the
specified value, and note
down the signal level.
00
Press PAUSE button.
Set data noted down at step 6,
and press PAUSE button.
00
00
00
Perform "REC AFM Current
Adjustment" and "Processing
after Completed Adjustment".
Center of the luminance line width
1.35 µsec
Fig. 6-3-7

Hide quick links: