Electronically Aligning The System Lasers; Adjusting The Field Of View And Angle Offset For Each Dimensioner (Dm3610 User Interface) - Datalogic DM3610 Reference Manual

Two-head dimensioning system
Table of Contents

Advertisement

DIMENSIONING SETUP AND CALIBRATION

5.3 ELECTRONICALLY ALIGNING THE SYSTEM LASERS

5.3.1
Adjusting the Field of View and Angle Offset for Each
Dimensioner
The field of view (FOV) and angle offset of each DM3610 dimensioner must be adjusted
manually using the DM3610 User Interface to cover its portion of the dimensioning area over
the conveyor. Perform the following adjustments for each DM3610:
1. Configure your laptop PC's IP Address to be in the same network as the DM3610's IP
Address (example: 192.168.3.1) See section 4.1.2.
2. Connect your laptop computer to the DM3610 HEAD1 HOST port using either the CAB-
ETH-M0x M12-IP67 ETHERNET CABLE or CBL-1534-0.2 ADAPT.CABLE ETH M12-TO-
RJ45F.
3. Open a browser on the laptop computer, and type in the default IP address for the
DM3610 to which your PC is attached (HEAD1 - 192.168.3.101, HEAD2 -
192.168.3.102). The DM3610 User Interface opens in the browser window.
NOTE: Details on using the DM3610 User Interface are
available in the DM3610 Dimensioner Reference Manual,
Chapter 4.
4. Open a browser tab for both HEAD1 (192.168.3.101) and HEAD2 (192.168.3.102), and
log on to their user interfaces.
5. From the menu tree Modify Settings, navigate to Dimensioning | Calibration. The
Calibration window opens.
(DM3610 User Interface)
5
111

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents