iring diagram
In case Closed end connector is used instead of Terminal block
Fig. D-4
Put Closed end connector between Brush holder (19) and Cord clamp (7).
Do not put Closed end connector on Rib G (rG).
Put Lead wire (blue) of Power supply cord and Lead wire (white) of Noise suppressor
that are connected to Switch (4) between Rib E (rE) and Rib G (rG).
(19)
(19)
(rG)
Wiring
(7)
(4)
(rE)