Sure Cross
®
Datasheet
®
The Sure Cross
wireless system is a radio frequency network with integrated I/O that can operate in most environments
and eliminate the need for wiring runs. Wireless networks are formed around a Gateway, which acts as the wireless
network master device, and one or more Nodes.
For additional information, updated documentation, and accessories, refer to Banner Engineering's website,
www.bannerengineering.com/surecross.
Models
Frequency
DX80N9X6S-P2
900 MHz ISM Band
DX80N2X6S-P2
2.4 GHz ISM Band
DX80...C (IP20; NEMA 1) models are also available. To order this model with an IP20 housing, add
a C to the end of the model number: DX80N9X6S-P2C.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
CAUTION: Never Operate 1 Watt Radios Without Antennas
To avoid damaging the radio circuitry, never power up Sure Cross
MultiHop (1 Watt) radios without an antenna.
CAUTION: Electrostatic Discharge (ESD)
ESD Sensitive Device. This product uses semiconductors that can be damaged by electrostatic
discharge (ESD). When performing maintenance, care must be taken so the device is not damaged.
Disconnect power from the device when accessing the internal DIP switches. Proper handling
procedures include wearing anti-static wrist straps. Damage from inappropriate handling is not covered
by warranty.
Original Document
155862 Rev. G
Performance Node
Wireless industrial I/O device with four selectable discrete inputs, four
sourcing discrete outputs, two universal analog inputs, and two 0 to 20 mA
analog outputs
Selectable transmit power levels of 250 mW or 1 Watt for 900 MHz models
and 65 mW for 2.4 GHz models
10 to 30 V dc power input
DIP switches for user configuration
Frequency Hopping Spread Spectrum (FHSS) technology and Time Division
Multiple Access (TDMA) control architecture ensure reliable data delivery
within the unlicensed Industrial, Scientific, and Medical (ISM) band
Transceivers provide bidirectional communication between the Gateway and
Node, including fully acknowledged data transmission
Lost RF links are detected and relevant outputs set to user-defined
conditions
Environmental
Rating
IP67, NEMA 6
I/O
Inputs: Four selectable discrete, two 0 to 20 mA (default) or
0 to 10 V (user configurable)
Outputs: Four sourcing discrete, two 0 to 20 mA
®
Performance or Sure Cross
15 May 2016
155862

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sure Cross DX80N9X6S-P2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Banner Sure Cross DX80N9X6S-P2

  • Page 1 Transceivers provide bidirectional communication between the Gateway and Node, including fully acknowledged data transmission • Lost RF links are detected and relevant outputs set to user-defined conditions For additional information, updated documentation, and accessories, refer to Banner Engineering's website, www.bannerengineering.com/surecross. Models Frequency Environmental...
  • Page 2: Setting Up Your Wireless Network

    DX80 radio, connect a computer to the DXM Controller using a USB or Ethernet connection. Download the most recent revisions of the UCT software from Banner Engineering's website: http://www.bannerengineering.com/wireless. The USB to RS-485 adapter cable is not required for the DXM Controller. For standalone DX80 Gateway devices use: •...
  • Page 3 ® Sure Cross Performance Node 2. Remove the cover from the housing without damaging the ribbon cable or the pins the cable plugs into. 3. Gently unplug the ribbon cable from the board mounted into the bottom housing. 4. Remove the black cover plate from the bottom of the device's cover. The DIP switches are located behind the rotary dials.
  • Page 4 Performance and non-Performance radios within the same network, refer the technical note titled Mixing Performance Radios and 150 mW Radios in the Same Network listed on the Wireless Support - FAQs section of Banner's Wireless website.
  • Page 5 ® Sure Cross Performance Node 5-Pin M12/Euro-style Male Quick Disconnect Integral 5-pin M12/Euro-style male quick disconnect (QD) wiring depends on the model and power requirements of the device. Not all models can be powered by 10 to 30 V dc and not all models can be powered by 3.6 to 5.5 V dc. Refer to Specifications to verify the power requirements of your device.
  • Page 6 ® Sure Cross Performance Node Discrete Input Wiring for PNP Sensors Discrete Input Wiring for NPN Sensors 10-30V dc Discrete IN Discrete IN dc common Wiring Diagrams for Discrete Outputs Connecting dc power to the communication pins will cause permanent damage. For the DX8x...C models, PWR in the wiring diagram refers to V+ on the wiring board and GND in the wiring diagram refers to V- on the wiring board.
  • Page 7: Modbus Registers

    ® Sure Cross Performance Node LED 1 LED 2 Node Status Flashing green Radio Link Ok Flashing red Flashing red Device Error Flashing red, 1 per 3 sec No Radio Link Modbus Registers Modbus Holding Register I/O Type Units I/O Range Holding Register Representation Gateway...
  • Page 8: Specifications

    ® Sure Cross Performance Node Specifications Radio Range Supply Voltage 900 MHz, 1 Watt: Up to 9.6 km (6 miles) 10 to 30 V dc (Outside the USA: 12 to 24 V dc, ±10%). 2.4 GHz, 65 mW: Up to 3.2 km (2 miles) 900 MHz Consumption: Maximum current draw is <...
  • Page 9 Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties.

This manual is also suitable for:

Sure cross dx80n2x6s-p2

Table of Contents