Advertisement

Quick Links

Table of Contents

Overview .................................................. 1
Setting Up ................................................ 2
STEP 1: Set NID & Device Address . 4
STEP 5: SiteSurvey ...................... 7
Host Network ........................................... 8
Product Dimensions ............................... 11
Menu System ........................................... 12
Troubleshooting ....................................... 16
Printed in USA
DX80 Quick Start Guide
A setup guide for the DX80 wireless system
Introducing the Banner DX80 Wireless System
The DX80 wireless system provides continuous monitoring without the burden of wiring or
conduit installation, and can operate independently or in conjunction with a PLC and/or PC
software. Configurations of the DX80 wireless system are shown below.
Model Number
DX80K
*
M6DP1
DX80K
*
M6DP2
DX80K
M6DP4
*
DX80K
M6DP7
*
Model Number
DX80K
*
M6MP1
DX80K
*
M6MP2
DX80K
M6MP7
*
Model Number
DX80K
R6DP1
*
DX80K
R6DP2
*
DX80K
*
R6DP4
DX80K
*
R6MP1
DX80K
R6MP2
*
Model Number
DX80K
*
S6DP
*
DX80K
*
S6MP
*
DX80K
S3PE
*
*
DX80K
S3GE
*
*
Model Number
DX80K
*
M3PE1
DX80K
*
M3GE1
DX80K
S3PE
*
*
DX80K
*
S3GE
*
DX80K
*
R3PE1
DX80K
R3GE1
*
09/06
All Digital
Digital and Analog
Repeater
Host-Connected
Up to 7 Nodes
FLEX Power
DX81
Battery Module
P/N 128185

Advertisement

Table of Contents
loading

Summary of Contents for Banner M6DP1

  • Page 1: Table Of Contents

    DX80 Quick Start Guide A setup guide for the DX80 wireless system Introducing the Banner DX80 Wireless System The DX80 wireless system provides continuous monitoring without the burden of wiring or conduit installation, and can operate independently or in conjunction with a PLC and/or PC software.
  • Page 2: Setting Up

    Six-character display provides run mode user information and shows enabled I/O point status. This display allows the user to conduct a Site Survey (RSSI), assign Network ID, and modify other DX80 configuration parameters without the use of a PC or other external software interfaces. Banner Engineering Corp. Minneapolis, MN U.S.A. •...
  • Page 3 Port, PG-7 Gland or Blank PG-7 threaded port can accept provided cable glands or blanks. Ribbon Connector Ribbon cable connects wiring base to LCD/radio. 5-Pin M12 Euro-style quick-disconnect fitting Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 P/N 128185...
  • Page 4 GETTING STARTED – NETWORK SETUP Quick Start: STEP 1 > Set Network ID & Device/Node Address The Banner DX80 wireless system is a network of devices consisting of a Gateway and Node(s). Network ID (NID) Device Address The network is defined by the Network ID (NID) assigned to the Gateway and its Node(s).
  • Page 5: Quick Start

    Indicates the current status of the I/O. The display will cycle through each I/O point of the device, then Brown 10-30V dc Input return to *RUN. Blue Ground Input repeat Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 P/N 128185...
  • Page 6: Step 4: Verify Communications

    Green ON — — Green FLASHING RF Link OK — Red ON System Error System Error Red FLASHING — No RF Link with Gateway (out of sync) Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 P/N 128185...
  • Page 7: Step 5: Sitesurvey

    Move back to the top level menu Single-click Gateway push button 1 Return to RUN mode Single-click Gateway push button 1 Single-click Gateway push button 1 Install Gateway rotary switch access cover. Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 P/N 128185...
  • Page 8: Host Network

    Ground Input Defines serial parity (none, even, or odd) Parity (default = none) Black RS485 / D0 / A / - between Gateway and Host. Grey Comms Gnd Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 P/N 128185...
  • Page 9 Parity setting is saved. Returns to Device Double-click Gateway push button 2 Configuration menu Click Gateway push button 1 through to *RUN Adjust Left rotary switch back to NID value Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 P/N 128185...
  • Page 10 Increase Height of DX80 Units The external antenna should be vertically- oriented for optimal RF communication. In addition, consider the height of DX80 position to improve reception levels. Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 P/N 128185...
  • Page 11: Product Dimensions

    65.0 mm (2.56˝) 65.0 mm 80.3 mm 126.7 mm (2.56˝) (3.16˝) (4.99˝) TOP VIEW SIDE VIEW 59.3 mm (2.33˝) 80.8 mm (3.18˝) 121.8 mm (4.79˝) BOTTOM VIEW Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 P/N 128185...
  • Page 12: Menu System

    Push Button 2 twice to return to the top level menu. Navigating the menu: = Top level < > = Sub-menu item No characters = Value of previous item Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 P/N 128185...
  • Page 13 < > = Sub-menu item No characters = Value of previous item Node LCD Timeout: Press any button to refresh the display if the Node has entered this energy- saving mode. Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 P/N 128185...
  • Page 14: Troubleshooting

    RF Link Time-out & Recovery Banner DX80 wireless devices employ a deterministic link time-out method to address RF link interruption or failure. As soon as a specific Node/Gateway RF link times out, all pertinent wired outputs are de-energized until the link is recovered (see kit-specific Supplemental Sheet for more information).
  • Page 15 Link between Gateway and Node 1 timed out. Link between Gateway and Node 1 recovered. It is the responsibility of the Host to handle Node device error messages. This will result in outputs being reinstated. Banner Engineering Corp. Minneapolis, MN U.S.A. •...
  • Page 16: Troubleshooting

    Also verify that the LCD on the output side mirrors the linked input’s behavior. If the input device state, LCD on origination working DX80, and LCD on destination DX80 all behave exactly the same, there may be a wiring issue or an interfacing problem. Consult factory. Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164...
  • Page 17 Part Number Antenna Type Maximum Gain — Integral antenna Unity gain 1/2 wave dipole ≤2 dBi Collinear ≤5 dBi Coaxial ≤7 dBi Table 1. Type certified Antenna Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 P/N 128185...
  • Page 18 DX80 Quick Start Guide Notes Banner Engineering Corp. Banner Engineering Corp. Minneapolis, MN U.S.A. Minneapolis, MN U.S.A. • • www.bannerengineering.com • Tel: 763.544.3164 www.bannerengineering.com • Tel: 763.544.3164 P/N 128185 P/N 128185...
  • Page 19 DX80 Quick Start Guide Notes Banner Engineering Corp. Banner Engineering Corp. Minneapolis, MN U.S.A. Minneapolis, MN U.S.A. • • www.bannerengineering.com • Tel: 763.544.3164 www.bannerengineering.com • Tel: 763.544.3164 P/N 128185 P/N 128185...
  • Page 20 Banner products. This warranty is in lieu of any other warranty either expressed or implied. Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com...

This manual is also suitable for:

M6dp4M6dp2Dx80kM6dp7

Table of Contents